DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PERFORM DTC CONFIRMATION PROCEDURE
1. Depress brake pedal and wait 1 second or more.
2. Check DTC in Self Diagnostic Result mode of BCM using CONSULT.
Is DTC detected?
YES >> Go to SEC Diagnosis Procedure.
NO >> Inspection End.
Regarding Wiring Diagram information, refer to SEC "Wiring Diagram".
1.CHECK STOP LAMP SWITCH INPUT SIGNAL 1
1. Turn ignition switch OFF.
2. Disconnect BCM connector.
3. Check voltage between BCM harness connector and ground.
Is the inspection normal?
YES >> GO TO 2.
NO-1 >> Check 10 A fuse [No. 30, located in the fuse block (J/B)].
NO-2 >> Check harness for open or short between BCM and fuse.
2.CHECK STOP LAMP SWITCH POWER SUPPLY CIRCUIT
1. Disconnect stop lamp switch connector.
2. Check voltage between stop lamp switch harness connector and ground.
Is the inspection result normal?
YES >> GO TO 3.
NO >> Check harness for open or short between stop lamp switch and fuse.
3.CHECK STOP LAMP SWITCH INPUT SIGNAL 2
1. Connect stop lamp switch connector.
2. Check voltage between BCM harness connector and ground.
Is the inspecting result normal?
YES >> GO TO 4.
NO >> GO TO 5.
4.REPLACE BCM
1. Replace BCM. Refer to BCS "Removal and Installation".
2. Perform initialization of BCM and registration of all Intelligent Keys using CONSULT.
>> Inspection End.
5.CHECK STOP LAMP SWITCH CIRCUIT
1. Disconnect stop lamp switch connector.
2. Check continuity between stop lamp switch harness connector and BCM
harness connector.
3. Check continuity between stop lamp switch harness connector and ground.
Is the inspection result normal?
YES >> GO TO 6.
NO >> Repair or replace harness.
6.CHECK STOP LAMP SWITCH
Refer to SEC "Component Inspection".
Is the inspection result normal?
YES >> GO TO 7.
NO >> Replace stop lamp switch. Refer to BR "Exploded View".
7.CHECK INTERMITTENT INCIDENT
Refer to GI "Intermittent Incident".
>> Inspection End.
1.CHECK STOP LAMP SWITCH
1. Turn ignition switch OFF.
2. Disconnect stop lamp switch connector.
3. Check continuity between stop lamp switch terminals.
Is the inspection result normal?
YES >> Inspection End.
NO >> Replace stop lamp switch. Refer to BR "Exploded View".
P074C Unable to engage 4GR
Description
This malfunction is detected when the A/T does not shift into 4GR position as
instructed by TCM. This is not
only caused by electrical malfunction (circuits open or shorted) but by
mechanical malfunction such as control
valve sticking, improper solenoid valve operation, etc.
DTC ...
P2760 Torque converter
Description
This DTC is detected when the torque converter clutch solenoid valve is
electrically normal but the torque converter
clutch does not engage. This is not due to an electrical malfunction (circuit
open or shorted), but is
instead due to a mechanical malfunction (sticking of the con ...