Description
Performs operation method guide and warning with buzzer.
1.CHECK FUNCTION
With CONSULT
Is the inspection result normal?
YES >> Warning buzzer into combination meter is OK.
NO >> Refer to DLK "Diagnosis Procedure".
1.CHECK METER BUZZER CIRCUIT
Operate the hazard lights by turning ON the hazard warning switch.
Is the inspection result normal?
YES >> GO TO 2
NO >> Replace combination meter. Refer to MWI "Removal and Installation" (type B) or MWI "Removal and Installation" (type A).
2.CHECK INTERMITTENT INCIDENT
Refer to GI "Intermittent Incident".
>> Inspection End.
Horn functionDescription Perform answer-back for each operation with horn. ...

Description Perform answer-back for each operation with number of blinks. Component Function Check 1.CHECK FUNCTION Check hazard warning lamp ("FLASHER") in Active Test. Is the inspection resul ...
Sun visors
1. To block glare from the front, swing down
the sun visor 1 .
2. To block glare from the side, remove the sun
visor from the center mount and swing the
visor to the side 2 .
3. Slide the extension 3 sun visor in or out as
needed.
CAUTION
Do not store the sun visor before returning
...
Spark plug
Exploded View
1. Ignition coil 2. Spark plug
Removal and Installation
REMOVAL
1. Remove ignition coil.
CAUTION:
Do not drop or shock ignition coil.
2. Remove spark plug using a suitable tool.
Diameter (a) : 14 mm (0.55 in)
CAUTION:
Do not drop or shock spark plug.
INSPECTION AFTER REM ...