Component Function Check
1.CHECK FUNCTION
Is the inspection result normal?
YES >> Hazard warning lamp circuit is OK.
NO >> Refer to DLK "Diagnosis Procedure".
Diagnosis Procedure
1.CHECK HAZARD SWITCH CIRCUIT
Refer to EXL "Component Function Check".
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace harness.
2.CHECK INTERMITTENT INCIDENT
Refer to GI "Intermittent Incident".
>> Inspection End.
P074B Unable to engage 3GR
Description
This malfunction is detected when the A/T does not shift into 3GR position as
instructed by TCM. This is not
only caused by electrical malfunction (circuits open or shorted) but by
mechanical malfunction such as control
valve sticking, improper solenoid valve operation, etc.
DTC ...
Main power supply and ground circuit
Diagnosis Procedure
1.CHECK TCM POWER CIRCUIT (PART 1)
Turn ignition switch OFF.
Disconnect TCM connector.
Check voltage between TCM harness connector terminals and ground.
Is the inspection result normal?
YES >> GO TO 2.
NO >> G ...