DTC DETECTION LOGIC
DTC No. | Trouble diagnosis name | DTC detecting condition | Possible cause |
P0182 | FTT SEN/CIRCUIT (Fuel tank temperature sensor circuit low input) | An excessively low voltage from the sensor is sent to ECM. |
|
P0183 | FTT SEN/CIRCUIT (Fuel tank temperature sensor circuit high input) | An excessively high voltage from the sensor is sent to ECM. |
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
>> GO TO 2.
2.PERFORM DTC CONFIRMATION PROCEDURE
Is 1st trip DTC detected?
YES >> Proceed to EC, "Diagnosis Procedure".
NO >> INSPECTION END
1.CHECK DTC WITH COMBINATION METER
Check DTC with combination meter. Refer to MWI, "CONSULT Function" (TYPE A) or MWI, "CONSULT Function" (TYPE B). Check the vehicle type to confirm the service information in MWI section. Refer to MWI, "Information".
Is the inspection result normal?
YES >> GO TO 2.
NO >> Proceed to MWI, "Component Function Check" (TYPE A) or MWI, "Component Function Check" (TYPE B).
2.CHECK FUEL TANK TEMPERATURE (FTT) SENSOR POWER SUPPLY
Is the inspection result normal?
YES >> GO TO 4.
NO >> GO TO 3.
3.CHECK FUEL TANK TEMPERATURE (FTT) SENSOR POWER SUPPLY CIRCUIT
4. Also check harness for short to ground and to power.
Is the inspection result normal?
YES >> Perform the trouble diagnosis for power supply circuit.
NO >> Repair or replace errordetected parts.
4.CHECK FUEL TANK TEMPERATURE (FTT) SENSOR GROUND CIRCUIT
4. Also check harness for short to power.
Is the inspection result normal?
YES >> GO TO 5.
NO >> Repair or replace errordetected parts.
5.CHECK FUEL TANK TEMPERATURE (FTT) SENSOR
Check the FTT sensor. Refer to EC, "Component Inspection".
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI, "Intermittent Incident".
NO >> Replace "fuel level sensor unit and fuel pump". Refer to FL, "Removal and Installation".
1.CHECK FUEL TANK TEMPERATURE (FTT) SENSOR
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace fuel level sensor unit and fuel pump. Refer to FL, "Removal and Installation".
Blower fan on signal
Component Function Check
1.CHECK BLOWER FAN ON SIGNAL
With CONSULT
Turn ignition switch ON.
Select "AIR CONDITIONER" of "BCM" using CONSULT.
Select "FAN ON SIG" in "DATA MONITOR" mode, and check status under the
following condition.
Is the inspection result normal?
YES >> I ...
CAN Communication circuit
Diagnosis Procedure
1.CONNECTOR INSPECTION
1. Turn the ignition switch OFF.
2. Disconnect the battery cable from the negative terminal.
3. Disconnect all the unit connectors on CAN communication system.
4. Check terminals and connectors for damage, bend and loose connection.
Is the inspection ...