Component Function Check
1.CHECK ABS WARNING LAMP FUNCTION
Check that ABS warning lamp in combination meter turns ON for approximately 2 seconds after ignition switch is turned ON.
Is the inspection result normal?
YES >> Inspection End.
NO >> Proceed to diagnosis procedure. Refer to BRC "Diagnosis Procedure".
Diagnosis Procedure
1.PERFORM THE SELF-DIAGNOSIS
With CONSULT.
Perform self diagnostic result.
Are any DTCs detected?
YES >> Refer to BRC "DTC Index".
NO >> GO TO 2.
2.CHECK COMBINATION METER
Check if indication and operation of combination meter are normal. Refer to MWI "METER SYSTEM : System Description" (type A) and MWI "METER SYSTEM : System Description" (type B).
Is the inspection result normal?
YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC "Removal and Installation".
NO >> Replace combination meter. Refer to MWI "Removal and Installation" (type A) or MWI "Removal and Installation" (type B).
VDC OFF SwitchComponent Function Check 1.CHECK VDC OFF SWITCH OPERATION Check that VDC OFF indicator lamp in combination meter turns ON/OFF when VDC OFF switch is operated. Is the inspection result normal? ...
Spark plugs
Replacing spark plugs
Platinum-tipped spark plugs
It is not necessary to replace platinum-tipped A
spark plugs as frequently as conventional type
spark plugs because they last much longer. Follow
the maintenance log shown in the Maintenance
and Schedules section of this manual. Do
not ser ...
P0731 1GR Incorrect ratio
Description
This malfunction is detected when the A/T does not shift into 1GR position as
instructed by TCM. This is not
only caused by electrical malfunction (circuits open or shorted) but by
mechanical malfunction such as control
valve sticking, improper solenoid valve operation, etc.
DTC ...