Description
Performs operation method guide and warning with buzzer.
1.CHECK FUNCTION
With CONSULT
Is the inspection result normal?
YES >> Warning buzzer into combination meter is OK.
NO >> Refer to DLK "Diagnosis Procedure".
1.CHECK METER BUZZER CIRCUIT
Operate the hazard lights by turning ON the hazard warning switch.
Is the inspection result normal?
YES >> GO TO 2
NO >> Replace combination meter. Refer to MWI "Removal and Installation" (type B) or MWI "Removal and Installation" (type A).
2.CHECK INTERMITTENT INCIDENT
Refer to GI "Intermittent Incident".
>> Inspection End.
Horn functionDescription Perform answer-back for each operation with horn. ...

Description Perform answer-back for each operation with number of blinks. Component Function Check 1.CHECK FUNCTION Check hazard warning lamp ("FLASHER") in Active Test. Is the inspection resul ...
Push starting
CAUTION
Do not push start this vehicle. The
three-way catalyst may be damaged
Continuously Variable Transmission
(CVT) and Manual Transmission models
cannot be push-started or tow-started.
Attempting to do so may cause transmission
damage.
For manual transmission models, never
...
Idle neutral control
IDLE NEUTRAL CONTROL : System Description
SYSTEM DIAGRAM
DESCRIPTION
If a driver has no intention of starting the vehicle in D position, TCM
operates the low brake solenoid valve and
controls the oil pressure of the low brake to be low pressure. Therefore, the
low brake is in the release ...