1.CHECK COOLING FAN FUNCTION
With CONSULT
NOTE: The cooling fan operates at high speeds even when "LOW" is selected in CONSULT "ACTIVE TEST". (For single connector cooling fan without A/C models)
Without CONSULT
Is the inspection result normal?
YES >> INSPECTION END
NO >> Refer to EC, "Diagnosis Procedure".
FOR SINGLE CONNECTOR COOLING FAN WITHOUT A/C MODELS
1.CHECK COOLING FAN MOTOR CIRCUIT
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
2.CHECK COOLING FAN MOTOR
Refer to EC, "Component Inspection (Cooling Fan Motor)".
Is the inspection result normal?
YES >> GO TO 3.
NO >> Replace cooling fan motor. Refer to CO, "Removal and Installation".
3.CHECK INTERMITTENT INCIDENT
Perform GI, "Intermittent Incident".
Is the inspection result normal?
YES >> Replace IPDM E/R. Refer to PCS, "Removal and Installation" (WITH I-KEY) or PCS, "Removal and Installation" (WITHOUT I-KEY).
NO >> Repair or replace harness or connector.
EXCEPT FOR SINGLE CONNECTOR COOLING FAN WITHOUT A/C MODELS
1.CHECK COOLING FAN MOTOR CIRCUIT
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
2.CHECK COOLING FAN RELAY CIRCUIT
Is the inspection result normal?
YES >> GO TO 3.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
3.CHECK COOLING FAN RELAY
Refer to EC, "Component Inspection (Cooling Fan Relay)".
YES or NO
YES >> GO TO 4.
NO >> Replace cooling fan relay.
4.CHECK COOLING FAN MOTOR
Refer to EC, "Component Inspection (Cooling Fan Motor)".
YES or NO
YES >> GO TO 5.
NO >> Replace cooling fan motor. Refer to CO, "Removal and Installation".
5.CHECK INTERMITTENT INCIDENT
Perform GI, "Intermittent Incident".
YES or NO
YES >> Replace IPDM E/R. Refer to PCS, "Removal and Installation" (WITH I-KEY) or PCS, "Removal and Installation" (WITHOUT I-KEY).
NO >> Repair or replace harness or connector.
1.CHECK COOLING FAN MOTOR
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace cooling fan motor. Refer to CO, "Removal and Installation".
Component Inspection (Cooling Fan Relay)
1.CHECK COOLING FAN RELAY
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace cooling fan relay.
Component Function Check 1.CHECK CLUTCH PEDAL POSITION SWITCH FUNCTION Turn ignition switch ON. Check the voltage between ECM harness connector and ground. Is the inspection result ...
Description The electrical load signal (Headlamp switch signal, rear window defogger switch signal, etc.) is transferred to ECM through the CAN communication line. ...
NISSAN Voice Recognition System (if so equipped)
The NISSAN Voice Recognition system allows
hands-free operation of the systems equipped on
this vehicle, such as the phone and navigation
systems.
To operate NISSAN Voice Recognition, press
the button located on the steering
wheel.
When prompted, speak the command for the
system you wi ...
Towing a trailer
Flat towing
Do not tow a trailer with your vehicle.
Towing your vehicle with all four wheels on the
ground is sometimes called flat towing. This
method is sometimes used when towing a vehicle
behind a recreational vehicle, such as a motor
home.
CAUTION
Failure to follow these guidelines c ...