Description
The front blower motor utilizes a brush-less motor with a rotating magnet. Quietness is improved over previous motors where the brush was the point of contact and the coil rotated.
Regarding Wiring Diagram information, refer to HAC "Wiring Diagram" or HAC "Wiring Diagram".
1.CHECK SYMPTOM
Check symptom (A or B).
Which symptom is detected?
A >>GO TO 2.
B >>GO TO 7.
2.CHECK FUSE
NOTE: Refer to PG "Terminal Arrangement".
Is the inspection result normal?
YES >> GO TO 3.
NO >> Replace the blown fuse after repairing the affected circuit.
3.CHECK FRONT BLOWER MOTOR POWER SUPPLY
Is the inspection result normal?
YES >> GO TO 5.
NO >> GO TO 4.
4.CHECK BLOWER RELAY
Is the inspection result normal?
YES >> Repair harness or connector between front blower motor and fuse.
NO >> Replace blower relay.
5.CHECK FAN SWITCH GROUND CIRCUIT FOR OPEN
Is the inspection result normal?
YES >> GO TO 6.
NO >> Repair harness or connector.
6.CHECK FAN SWITCH 4TH POSITION CIRCUIT FOR OPEN
Check continuity between front air control harness connector and front blower
motor harness connector.
Is the inspection result normal?
YES >> GO TO 10.
NO >> Repair the harness or connector.
7.CHECK FRONT BLOWER MOTOR RESISTOR POWER SUPPLY
Is the inspection result normal?
YES >> GO TO 8.
NO >> Repair harness or connector between front blower motor resistor and front blower motor.
8.CHECK FAN SWITCH 1ST, 2ND, AND 3RD POSITION CIRCUIT FOR OPEN
Is the inspection result normal?
YES >> GO TO 9.
NO >> Repair harness or connector.
9.CHECK FRONT BLOWER MOTOR RESISTOR
Check front blower motor resistor. Refer to HAC "Component Inspection (Front Blower Motor Resistor)".
Is the inspection result normal?
YES >> GO TO 10.
NO >> Replace front blower motor resistor. Refer to HAC "Removal and Installation".
10.CHECK FAN SWITCH
Check fan switch. Refer to HAC "Component Inspection (Fan Switch)".
Is the inspection result normal?
YES >> Replace front blower motor. Refer to VTL "Removal and Installation".
NO >> Replace front air control. Refer to HAC "Removal and Installation".
Component Inspection (Front Blower Motor)
1.CHECK FRONT BLOWER MOTOR
Does the front blower motor operate?
YES >> Intermittent incident. Refer to GI"Intermittent Incident".
NO >> Replace front blower motor. Refer to VTL "Removal and Installation".
1.CHECK BLOWER RELAY
Is the inspection result normal?
YES >> Inspection End.
NO >> Replace blower relay.
Component Inspection (Front Blower Motor Resistor)
1.CHECK FRONT BLOWER MOTOR RESISTOR
Is the inspection result normal?
YES >> Inspection End.
NO >> Replace front blower motor resistor. Refer to HAC "Removal and Installation".
Component Inspection (Fan Switch)
1.CHECK FAN SWITCH
Is the inspection result normal?
YES >> Inspection End.
NO >> Replace front air control. Refer to HAC "Removal and Installation".
Diagnosis Procedure Regarding Wiring Diagram information, refer to HAC "Wiring Diagram" or HAC "Wiring Diagram". 1.CHECK A/C INDICATOR POWER SUPPLY Turn ignition switch O ...
Intake manifold
Exploded View
1. EVAP canister purge volume control
solenoid valve
2. Hose clamp 3. Vacuum hose
4. PCV hose 5. Hose clamp 6. Intake manifold support
7. Gasket 8. Intake manifold 9. Electric throttle control actuator
10. Gasket 11. EVAP service port
A. To air duct B. To centralized underf ...
Cylinder block
Exploded View
1. Crankshaft position sensor cover 2. Crankshaft position sensor (POS) 3.
Oring
4. Drain plug 5. Cylinder block 6. Oil level gauge
7. Oil level gauge guide 8. Oring 9. Knock sensor 10. Oil temperature sensor
11. Oil pressure sensor 12. Oil jet
13. Top ring 14. Second ring ...