The Supplemental Restraint System such as "AIR BAG" and "SEAT BELT PRE-TENSIONER", used along with a front seat belt, helps to reduce the risk or severity of injury to the driver and front passenger for certain types of collision. This system includes seat belt switch inputs and dual stage front air bag modules. The SRS system uses the seat belt switches to determine the front air bag deployment, and may only deploy one front air bag, depending on the severity of a collision and whether the front occupants are belted or unbelted.
Information necessary to service the system safely is included in the SR and SB section of this Service Manual.
WARNING:
PRECAUTIONS WHEN USING POWER TOOLS (AIR OR ELECTRIC) AND HAMMERS
WARNING:
Precautions for Trouble Diagnosis
CAUTION: Follow the instructions listed below. Failure to do this may cause damage to parts:
NOTE: A fray of twisted lines must be within 110 mm (4.33 in).

NOTE: Bypass connection may cause CAN communication error. The spliced wire becomes separated and the characteristics of twisted line are lost.

SYSTEM DESCRIPTION
COMPONENT PARTS
Component Parts Location

1. Combination meter
- M82: TYPE A
- M24: TYPE B
2. AV control unit M70
3. ABS actuator and electric unit (control unit) E33
4. TCM
- F44: CVT models
- F57: A/T models
5. ECM E16
6. IPDM E/R E46
7. EPS control unit M53
8. BCM
- M97: Models with Intelligent Key system
- M18: Models without Intelligent Key system
9. Data link connector M22
10. Steering angle sensor M64
11. Air bag diagnosis sensor unit M35
SYSTEM
Diagnosis and repair workflowTrouble Diagnosis Flow Chart Trouble Diagnosis Procedure INTERVIEW WITH CUSTOMER Interview with the customer is important to detect the root cause of CAN communication system errors and t ...
Power outlets
Instrument panel
Console (if so equipped)
The power outlets are for powering electrical
accessories such as cellular telephones. The
outlets are rated at 12 volt, 120W (10A) maximum.
CAUTION
The outlet and plug may be hot during
or immediately after use.
Only certain power outlets ...
P073E Unable to engage r range
Description
This malfunction is detected when the A/T does not shift into reverse
position as instructed by TCM. This is not
only caused by electrical malfunction (circuits open or shorted) but by
mechanical malfunction such as control
valve sticking, improper solenoid valve operation, etc
D ...