Description
Heats the heating wire with the power supply from the rear window defogger relay to prevent the door mirror from fogging up.
1. CHECK DOOR MIRROR DEFOGGER LH
Check that heating wire of door mirror defogger LH is heated when turning the rear window defogger switch ON.
Is the inspection result normal?
YES >> Door mirror defogger is OK.
NO >> Refer to DEF "Diagnosis Procedure".
Regarding Wiring Diagram information, refer to DEF "Wiring Diagram".
1. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect door mirror LH.
3. Turn ignition switch ON.
4. Check voltage between door mirror LH connector and ground.
Is the inspection result normal?
YES >> GO TO 2
NO >> Repair or replace harness.
2. CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Check continuity between door mirror LH connector and ground.
Is the inspection result normal?
YES >> GO TO 3
NO >> Repair or replace harness.
3. CHECK DOOR MIRROR DEFOGGER LH
Check door mirror defogger LH.
Refer to DEF "Component Inspection".
Is the inspection result normal?
YES >> GO TO 4
NO >> Replace door mirror. Refer to MIR "DOOR MIRROR ASSEMBLY : Removal and Installation".
4. CHECK INTERMITTENT INCIDENT
Check intermittent incident.
Refer to GI "Intermittent Incident".
Is the inspection result normal?
YES >> Check the following.
NO >> Repair or replace the malfunctioning parts.
1. CHECK DOOR MIRROR DEFOGGER LH
1. Turn ignition switch OFF.
2. Disconnect door mirror LH.
3. Check continuity between door mirror terminals.
Is the inspection result normal?
YES >> Inspection End.
NO >> Replace door mirror LH. Refer to MIR "DOOR MIRROR ASSEMBLY : Removal and Installation".
Rear window defogger power supply
and ground circuitDescription Heats the heating wire with the power supply from the rear window defogger relay to prevent the rear window from fogging up. ...

Description Heats the heating wire with the power supply from the rear window defogger relay to prevent the door mirror from fogging up. ...
Trunk lamp switch
Description
Detects trunk open/close condition.
Component Function Check
1.CHECK FUNCTION
With CONSULT
Check TRNK/HAT MNTR in Data Monitor mode with CONSULT.
Is the inspection result normal?
YES >> Trunk room lamp switch is OK.
NO >> Refer to DLK "Diagnosis ...
IGN OFF Interlock door unlock
function does not operate
Diagnosis Procedure
1.CHECK AUTOMATIC LOCK/UNLOCK SELECT SETTING IN WORK SUPPORT
Select DOOR LOCK of BCM using CONSULT.
Select AUTOMATIC LOCK/UNLOCK SELECT in WORK SUPPORT mode.
Check AUTOMATIC LOCK/UNLOCK SELECT setting in WORK SUPPORT.
Refer to BCS "DOOR LOCK : CONSULT Function ...