DTC DETECTION LOGIC
| DTC No. | Trouble diagnosis name | DTC detecting condition | Possible cause |
| P0447 | VENT CONTROL VALVE (EVAP canister vent control valve circuit open) | An improper voltage signal is sent to ECM through EVAP canister vent control valve. |
|
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
TESTING CONDITION: Before performing the following procedure, confirm battery voltage is more than 11 V at idle.
>> GO TO 2.
2.PERFORM DTC CONFIRMATION PROCEDURE
Is 1st trip DTC detected?
YES >> Proceed to EC, "Diagnosis Procedure".
NO >> INSPECTION END
1.INSPECTION START
Do you have CONSULT?
YES >> GO TO 2.
NO >> GO TO 3.
2.CHECK EVAP CANISTER VENT CONTROL VALVE CIRCUIT
With CONSULT
Clicking sound should be heard.
Is the inspection result normal?
YES >> GO TO 7.
NO >> GO TO 3.
3.CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY

Is the inspection result normal?
YES >> GO TO 5.
NO >> GO TO 4.
4.CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY CIRCUIT

Is the inspection result normal?
YES >> Perform the trouble diagnosis for power supply circuit.
NO >> Repair or replace errordetected parts.
5.CHECK EVAP CANISTER VENT CONTROL VALVE OUTPUT SIGNAL CIRCUIT

Is the inspection result normal?
YES >> GO TO 6.
NO >> Repair or replace errordetected parts.
6.CHECK RUBBER TUBE FOR CLOGGING
Is the inspection result normal?
YES >> GO TO 7.
NO >> Clean the rubber tube using an air blower.
7.CHECK EVAP CANISTER VENT CONTROL VALVE
Check the EVAP canister vent control valve. Refer to EC, "Component Inspection".
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI, "Intermittent Incident".
NO >> Replace EVAP canister vent control valve. Refer to FL, "Removal and Installation"
1.CHECK EVAP CANISTER VENT CONTROL VALVEI
Is it rusted?
YES >> Replace EVAP canister vent control valve. Refer to FL, "Removal and Installation".
NO >> GO TO 2.

2.CHECK EVAP CANISTER VENT CONTROL VALVEII
With CONSULT
Make sure new Oring is installed properly.
Operation takes less than 1
second.

Without CONSULT
Check air passage continuity and operation delay time under the following
conditions. Make sure new Oring is installed properly.
Operation takes less than 1
second.
Is the inspection result normal?
YES >> GO TO 3.
NO >> Replace EVAP canister vent control valve. Refer to FL, "Removal and Installation".
3.CHECK EVAP CANISTER VENT CONTROL VALVEIII
With CONSULT
Make sure new Oring is installed properly.
Operation takes less than 1
second.

Without CONSULT
Operation
takes less than 1 second.Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace EVAP canister vent control valve. Refer to FL, "Removal and Installation".
Bluetooth Hands-Free Phone System without Navigation System (Type A) (if so
equipped)
WARNING
Use a phone after stopping your vehicle
in a safe location. If you have to use a
phone while driving, exercise extreme
caution at all times so full attention may
be given to vehicle operation.
If you are unable to devote full attention
to vehicle operation while talking on
...
P074B Unable to engage 3GR
Description
This malfunction is detected when the A/T does not shift into 3GR position as
instructed by TCM. This is not
only caused by electrical malfunction (circuits open or shorted) but by
mechanical malfunction such as control
valve sticking, improper solenoid valve operation, etc.
DTC ...