DTC Logic
DTC DETECTION LOGIC
| DTC | Trouble diagnosis name | DTC detection condition | Possible causes |
| P0979 | Shift Solenoid C Control Circuit Low | The following diagnosis conditions
are met, and the current
monitor reading of the TCM 2-4
brake solenoid valve is 200 mA
or less continuously for 0.5 seconds
or more. - Diagnosis condition - Solenoid valve output current: 750 mA or more - GND short circuit diagnosis occurs in the solenoid valve drive circuit. - TCM power supply voltage: 10 V < TCM power supply voltage < 16 V |
- Harness or connector
(Short circuit to ground in the
2-4 brake solenoid valve circuit) - 2-4 brake solenoid valve |
DTC REPRODUCTION PROCEDURE
CAUTION: Be careful of the driving speed.
1.PREPARATION BEFORE WORK
If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition switch OFF and wait for at least 10 seconds, then perform the next test.
>> GO TO 2.
2.CHECK DTC DETECTION
Selector lever : 2 position
Gear : 2GR
Vehicle speed : 20 km/h (13 MPH) or more
Is "P0979" detected?
YES >> Go to TM, "Diagnosis Procedure".
NO >> INSPECTION END
Diagnosis Procedure
1.CHECK CIRCUIT BETWEEN TCM AND A/T UNIT

Is the check result normal?
YES >> GO TO 2.
NO >> Repair or replace the malfunctioning parts.
2.CHECK 2-4 BRAKE SOLENOID VALVE
Check the 2-4 brake solenoid valve. Refer to TM, "Component Inspection (2-4 Brake Solenoid Valve)".
Is the check result normal?
YES >> Check intermittent incident. Refer to GI, "Intermittent Incident".
NO >> Repair or replace the malfunctioning parts.
Component Inspection (2-4 Brake Solenoid Valve)
1.CHECK 2-4 BRAKE SOLENOID VALVE
Check the resistance between the A/T unit connector and ground. 
Is the check result normal?
YES >> INSPECTION END
NO >> There is a malfunction of the 2-4 brake solenoid valve. Replace the transaxle assembly. Refer to TM, "Removal and Installation".
P0977 Shift solenoid BDTC Logic DTC DETECTION LOGIC DTC Trouble diagnosis name DTC detection condition Possible causes P0977 Shift Solenoid B Control Circuit High The following diagnosi ...

DTC Logic DTC DETECTION LOGIC DTC Trouble diagnosis name DTC detection condition Possible causes P0980 Shift Solenoid C Control Circuit High The following diagnosis ...
Doors
When the doors are locked using one of the
following methods, the doors cannot be opened
using the inside or outside door handles. The
doors must be unlocked to open the doors.
WARNING
Before opening any door, always look
for and avoid oncoming traffic.
To help avoid risk of injury or de ...
Trunk open function
TRUNK OPEN FUNCTION : System Description
System Diagram
TRUNK LID OPENER OPERATION
When the BCM detects that trunk lid opener switch is pressed, it starts
the outside key antenna (rear
bumper) and inside key antenna and transmits the request signal to the
Intelligent Key. Then, c ...