Nissan Versa (N17): Throttle valve closed position learning

Nissan Versa 2nd generation (N17) Service Manual / Engine / Engine control system (EC) / Throttle valve closed position learning

Description

Throttle Valve Closed Position Learning is a function of ECM to learn the fully closed position of the throttle valve by monitoring the throttle position sensor output signal. It must be performed each time harness connector of electric throttle control actuator or ECM is disconnected or electric throttle control actuator inside is cleaned.

Work Procedure

1.START

WITH CONSULT

  1. Turn ignition switch ON.
  2. Select "CLSD THL POS LEARN" in "WORK SUPPORT" mode.
  3. Follow the instructions on the CONSULT display.
  4. Turn ignition switch OFF and wait at least 10 seconds.

    Check that throttle valve moves during the above 10 seconds by confirming the operating sound.

WITHOUT CONSULT

  1. Start the engine.

    NOTE: Engine coolant temperature is 25C (77F) or less before engine starts.

  2. Warm up the engine.

    NOTE: Raise engine coolant temperature until it reaches 65C (149F) or more.

  3. Turn ignition switch OFF and wait at least 10 seconds.

    Check that throttle valve moves during the above 10 seconds by confirming the operating sound.

>> END

Accelerator pedal released position learning

Description Accelerator Pedal Released Position Learning is a function of ECM to learn the fully released position of the accelerator pedal by monitoring the accelerator pedal position sensor ou ...

Idle air volume learning

Description Idle Air Volume Learning is a function of ECM to learn the idle air volume that keeps each engine idle speed within the specific range. It must be performed under any of the followin ...

Other materials:

Exhaust manifold
Exploded View 1. Exhaust manifold cover 2. Harness bracket 3. Airfuel ratio sensor 1 4. Exhaust manifold stay 5. Heat insulator 6. Exhaust manifold 7. Exhaust manifold cover 8. Gasket : Engine front Removal and Installation REMOVAL Remove air duct (inlet), air duct and air cleaner as ...

Power supply and ground circuit
Diagnosis Procedure 1.CHECK GROUND CONNECTION Turn ignition switch OFF. Check ground connection E. Refer to Ground Inspection in GI, "Circuit Inspection". Is the inspection result normal? YES >> GO TO 2. NO >> Repair or replace ground connection. 2.CHECK ECM G ...