1.CHECK FUNCTION
Is the inspection result normal?
YES >> Trunk lid switch is OK.
NO >> Refer to DLK "Diagnosis Procedure".
Regarding Wiring Diagram information, refer to DLK "TRUNK LID OPENER SYSTEM : Wiring Diagram".
1.CHECK TRUNK LID OPENER INPUT SIGNAL
Is the inspection result normal?
YES >> GO TO 3.
NO >> GO TO 2.
2.CHECK TRUNK LID OPENER SWITCH CIRCUIT
Is the inspection result normal?
YES >> Replace BCM. Refer to BCS "Removal and Installation".
NO >> Repair or replace harness.
3.CHECK TRUNK LID SWITCH GROUND CIRCUIT
Check continuity between trunk lid switch harness connector and ground.
Is the inspection result normal?
YES >> GO TO 4.
NO >> Repair or replace harness.
4.CHECK TRUNK LID SWITCH
Refer to DLK "Component Function Check".
Is the inspection result normal?
YES >> GO TO 5.
NO >> Replace trunk lid switch.
5.CHECK INTERMITTENT INCIDENT
Refer to GI "Intermittent Incident".
>> Inspection End.
1.CHECK TRUNK LID SWITCH
Is the inspection result normal?
YES >> Inspection End.
NO >> Replace trunk lid switch.
Component Function Check 1.CHECK FUNCTION Select INTELLIGENT KEY of BCM using CONSULT. Select TRUNK/GLASS HATCH in ACTIVE TEST mode. Touch OPEN to check that it works normally. Is the insp ...
Description Detects trunk open/close condition. Component Function Check 1.CHECK FUNCTION With CONSULT Check TRNK/HAT MNTR in Data Monitor mode with CONSULT. Is the inspection ...
Preparation
Special Service Tool
The actual shape of Kent-Moore tools may differ from those of special service
tools illustrated here.
HFC-134a (R-134a) Service Tool and Equipment
Do not mix HFC-134a (R-134a) refrigerant and/or its specified oil with CFC-12
(R-12) refrigerant and/or its oil.
Separ ...
Power supply and ground circuit
Diagnosis Procedure
Regarding Wiring Diagram information, refer to PCS "Wiring Diagram".
1. CHECK FUSE AND FUSIBLE LINKS
Check that the following IPDM E/R fuse or fusible links are not blown.
Is the fuse blown?
YES >> Replace the blown fuse or fusible link after repairing the af ...