Nissan Versa (N17): Insufficient cooling

Nissan Versa 2nd generation (N17) Service Manual / Ventilation, heater & air conditioner / Heater & air conditioning control system (HAC) / Insufficient cooling

Description

Symptom

  • Insufficient cooling
  • No cool air comes out. (Air flow volume is normal.)

Diagnosis Procedure

NOTE: Perform self-diagnosis with CONSULT before performing symptom diagnosis. If any malfunction result or DTC is detected, perform the corresponding diagnosis.

1.CHECK MAGNET CLUTCH OPERATION

  1. Turn ignition switch ON.
  2. Turn fan control dial ON.
  3. Press A/C switch.
  4. Check that A/C indicator turns ON. Check visually and by sound that compressor operates.
  5. Press A/C switch again.
  6. Check that A/C indicator turns OFF. Check that compressor stops.

Is the inspection result normal?

YES >> GO TO 2.

NO >> Check compressor operation. Refer to HAC "Diagnosis Procedure".

2.CHECK DRIVE BELT

Check tension of drive belt. Refer to EM "Inspection".

Is the inspection result normal?

YES >> GO TO 3.

NO >> Adjust or replace drive belt depending on the inspection results.

3.CHECK REFRIGERANT CYCLE PRESSURE

Connect the recovery/recycling recharging equipment to the vehicle and perform the pressure inspection using gauge. Refer to HA "Symptom Table".

Is the inspection result normal?

YES >> GO TO 4.

NO >> Repair or replace parts depending on the inspection results.

4.CHECK AIR LEAKAGE FROM EACH DUCT

Check duct and nozzle, etc. of the air conditioner system for leakage.

Is the inspection result normal?

YES >> Check air mix door cable installation and air mix door operation.

NO >> Repair or replace parts depending on the inspection results.

Insufficient heating

Description Symptom Insufficient heating No warm air comes out. (Air flow volume is normal.) Diagnosis Procedure NOTE: Perform self-diagnosis with CONSULT before performing symptom diagn ...

Other materials:

P073F Unable to engage 1GR
Description This malfunction is detected when the A/T does not shift into 1GR position as instructed by TCM. This is not only caused by electrical malfunction (circuits open or shorted) but by mechanical malfunction such as control valve sticking, improper solenoid valve operation, etc. DTC ...

Oil pan
Exploded View 1. Transaxle assembly 2. Oil pan gasket 3. Magnet 4. Oil pan 5. Overflow tube 6. Drain plug gasket 7. Drain plug 8. Oil pan fitting bolt Removal and Installation REMOVAL Remove the drain plug and overflow tube, and then drain the CVT fluid.WARNING: CVT fluid can splash ...