Nissan Versa (N17): Outside handle

Nissan Versa 2nd generation (N17) Service Manual / Body exterior, doors, roof & vehicle security / Door & lock (DLK) / Outside handle

OUTSIDE HANDLE : Removal and Installation

REMOVAL

1. Fully close rear door glass.

2. Remove rear door finisher. Refer to INT "Removal and Installation".

3. Remove sealing screen.

NOTE: Cut the butyl tape so that some parts of the butyl tape remain on the sealing screen, if the sealing screen is reused.

4. Remove door side grommet, and loosen bolt from grommet hole.

REMOVAL

5. While pulling outside handle, remove outside handle escutcheon.

REMOVAL

6. Pull outside handle (1) rearward and outward to remove.

REMOVAL

7. Remove front gasket (1) and rear gasket (2).

: Front

REMOVAL

8. Slide outside handle bracket toward rear of vehicle to remove.

: Front

REMOVAL

9. Disconnect outside handle cable (1) from outside handle bracket (2) as shown.

REMOVAL

INSTALLATION

Installation is in the reverse order of removal.

CAUTION:

  • After installation, check door open/close, lock/unlock operation.
  • Check door lock cable is properly engaged with outside handle bracket.

TRUNK LID LOCK

Exploded View

Exploded View

1. Trunk lid opener handle 2. Trunk lid opener cable 3. Cable protector 4. Trunk lid striker 5. Trunk lid lock assembly 6. Key rod 7. Trunk key cylinder

Inside handle

INSIDE HANDLE : Removal and Installation REMOVAL 1. Remove rear door finisher. Refer to INT "Removal and Installation". 2. Remove upper side of sealing screen. NOTE: Cut the butyl tape ...

Trunk lid lock

TRUNK LID LOCK : Removal and Installation REMOVAL 1. Remove trunk lid finisher (if equipped). Refer to INT "Removal and Installation". 2. Release rod holder (1) by lifting upward, and ...

Other materials:

Description
Engine Cooling System M/T models CVT and A/T models Engine Cooling System Schematic M/T models CVT and A/T models OVERHEATING CAUSE ANALYSIS Troubleshooting Chart   Symptom Check items Cooling system parts malfunction Poor heat transfer ...

EVAP leak check
Inspection CAUTION: Do not use compressed air or a high pressure pump. Do not exceed 4.12 kPa (0.042 kg/cm2, 0.6 psi) of pressure in EVAP system. NOTE: Do not start engine. Improper installation of EVAP service port adapter [commercial service tool: (J-41413-OBD)] to the EVAP ...