DTC DETECTION LOGIC
DTC No. | Trouble diagnosis name (Trouble diagnosis content) | DTC detecting condition | Possible cause |
P0037 | HO2 HTR (B1) (Heated oxygen sensor 2 heater control circuit low) | The current amperage in the heated oxygen sensor 2
heater circuit is out of the normal range.
(An excessively low voltage signal is sent to ECM through the heated oxygen sensor 2 heater.) |
|
P0038 | HO2 HTR (B1) (Heated oxygen sensor 2 heater control circuit high) | The current amperage in the heated oxygen sensor 2
heater circuit is out of the normal range.
(An excessively high voltage signal is sent to ECM through the heated oxygen sensor 2 heater.) |
|
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
TESTING CONDITION: Before performing the following procedure, confirm that battery voltage is more than 11 V at idle.
>> GO TO 2.
2.PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT
With GST
Follow the procedure "With CONSULT" above.
Is 1st trip DTC detected?
YES >> Proceed to EC, "Diagnosis Procedure".
NO >> INSPECTION END
1.CHECK HO2S2 POWER SUPPLY CIRCUIT
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace errordetected parts.
2.CHECK HO2S2 OUTPUT SIGNAL CIRCUIT
4. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES >> GO TO 3.
NO >> Repair or replace errordetected parts.
3.CHECK HEATED OXYGEN SENSOR 2 HEATER
Check the heated oxygen sensor 2 heater. Refer to EC, "Component Inspection".
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI, "Intermittent Incident".
NO >> GO TO 4.
4.REPLACE HEATED OXYGEN SENSOR 2
Replace heated oxygen sensor 2. Refer to EX, "Exploded View".
CAUTION: - Discard any sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner [commercial service tool (J4389718 or J4389712)] and approved Antiseize Lubricant (commercial service tool).
>> INSPECTION END
1.CHECK HEATED OXYGEN SENSOR 2 HEATER
Is the inspection result normal?
YES >> INSPECTION END
NO >> GO TO 2.
2.REPLACE HEATED OXYGEN SENSOR 2
Replace heated oxygen sensor 2. Refer to EX, "Exploded View".
CAUTION:
>> INSPECTION END
Outside handle
OUTSIDE HANDLE : Removal and Installation
REMOVAL
1. Fully close rear door glass.
2. Remove rear door finisher. Refer to INT "Removal and Installation".
3. Remove sealing screen.
NOTE:
Cut the butyl tape so that some parts of the butyl tape remain on the sealing
screen, if the se ...
BCM
Reference Value
NOTE:
The Signal Tech II Tool (J-50190) can be used to perform the following
functions. Refer to the Signal Tech II
User Guide for additional information.
Activate and display TPMS transmitter IDs
Display tire pressure reported by the TPMS transmitter
Read TPMS DTCs
...