DTC DETECTION LOGIC
DTC No. | Trouble diagnosis name | DTC detecting condition | Possible cause |
P0075 | Intake valve timing control solenoid valve circuit | An improper voltage is sent to the ECM through intake valve timing control solenoid valve. |
|
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
>> GO TO2.
2.PERFORM DTC CONFIRMATION PROCEDURE
Is 1st trip DTC detected?
YES >> Go to EC, "Diagnosis Procedure".
NO >> INSPECTION END
1.CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
Is the inspection result normal?
YES >> GO TO 3.
NO >> GO TO 2.
2.DETECT MALFUNCTIONING PART
Check the following.
>> Repair open circuit or short to ground or short to power in harness or connectors.
3.CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
4. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES >> GO TO 4.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
4.CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE
Refer to EM, "Exploded View".
Is the inspection result normal?
YES >> GO TO 5.
NO >> Replace intake valve timing control solenoid valve. Refer to EM, "Exploded View".
5.CHECK INTERMITTENT INCIDENT
Refer to GI, "Intermittent Incident".
>> INSPECTION END
1.CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVEI
Is the inspection result normal?
YES >> GO TO 2.
NO >> Replace intake valve timing control solenoid valve. Refer to EM, "Exploded View".
2.CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVEII
CAUTION: Do not apply 12 V continuously for 5 seconds or more.
Doing so may result in damage to the coil in intake valve timing control solenoid valve.
NOTE: Always replace Oring when intake valve timing control solenoid valve is removed.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace intake valve timing control solenoid valve.
Trunk lid opener actuator
Component Function Check
1.CHECK FUNCTION
Select INTELLIGENT KEY of BCM using CONSULT.
Select TRUNK/GLASS HATCH in ACTIVE TEST mode.
Touch OPEN to check that it works normally.
Is the inspection result normal?
YES >> Trunk lid opener actuator is OK.
NO >> Refer to DLK " ...
Key switch (BCM Input)
Diagnosis Procedure
Regarding Wiring Diagram information, refer to DLK "Wiring Diagram".
1.CHECK KEY SWITCH INPUT SIGNAL
With CONSULT
Check key switch "KEY ON SW" in DATA MONITOR mode with CONSULT. Refer to BCS
"DOOR LOCK :
...