Security indicator lamp does not blink when power supply position is other than the ON position.
NOTE:
Conditions of Vehicle (Operating Conditions) Power supply position is other than the ON position.
1.CHECK SECURITY INDICATOR LAMP
Check security indicator lamp.
Refer to DLK "Component Function Check".
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace the malfunctioning parts.
2.CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES >> Check intermittent incident. Refer to GI"Intermittent Incident".
NO >> GO TO 1.
REMOVAL AND INSTALLATION

Removal and Installation REMOVAL 1. Remove the instrument lower panel LH. Refer to IP"Removal and Installation". 2. Release the NATS antenna amp. pawls and remove NATS antenna amp. (1) ...
Evaporative emission system
Inspection
1.CHECK EVAP CANISTER
Block port (B).
Blow air into port (A) and check that it flows freely out of port (C).
Release blocked port (B).
Apply vacuum pressure to port (B) and check that vacuum pressure
exists at the ports (A) and (C).
Block port (A) and (B).
Apply pressure ...
P074A Unable to engage 2GR
Description
This malfunction is detected when the A/T does not shift into 2GR position as
instructed by TCM. This is not
only caused by electrical malfunction (circuits open or shorted) but by
mechanical malfunction such as control
valve sticking, improper solenoid valve operation, etc.
DTC ...