NOTE: The Signal Tech II Tool (J-50190) can be used to perform the following functions. Refer to the Signal Tech II User Guide for additional information.
DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE
1.PERFORM SELF DIAGNOSTIC RESULT
With CONSULT
Is DTC "C1729" detected?
YES >> Proceed to WT "Diagnosis Procedure".
NO >> Inspection End.
NOTE: The Signal Tech II Tool (J-50190) can be used to perform the following functions. Refer to the Signal Tech II User Guide for additional information.
1.PERFORM COMBINATION METER SELF DIAGNOSTIC RESULT
With CONSULT
Perform "SELF DIAGNOSTIC RESULT" for "METER/M&A". Refer to MWI "CONSULT Function" (type B) or MWI "CONSULT Function" (type A).
Are any DTCs detected?
YES >> Refer to MWI "DTC Index" (type B) or MWI "DTC Index" (type A).
NO >> GO TO 2.
2.CHECK BCM INPUT/OUTPUT SIGNAL
Check the BCM input/output signal values. Refer to BCS "Reference Value" or BCS "Reference Value".
Is the inspection result normal?
YES >> Check pin terminal and connection of each harness connector for malfunctioning conditions.
NO >> Replace the BCM. Refer to BCS "Removal and Installation" or BCS "Removal and Installation".

Component Function Check 1.CHECK THE ILLUMINATION OF THE LOW TIRE PRESSURE WARNING LAMP Check that the low tire pressure warning lamp is turned OFF after illuminating for approximately 1 second, ...
Refrigeration system
Refrigerant Cycle
REFRIGERANT FLOW
The refrigerant flows in the standard pattern, that is, through the
compressor, the condenser with liquid tank,
through the evaporator, and back to the compressor. The refrigerant evaporation
through the evaporator coils
are controlled by externally equaliz ...
Door does not lock/unlock with
driver side door lock knob or door
key cylinder
Diagnosis Procedure
1.CHECK POWER DOOR LOCK OPERATION
Check power door lock operation.
Does door lock/unlock with door lock and unlock switch?
YES >> GO TO 2.
NO >> Refer to DLK "ALL DOOR : Diagnosis Procedure".
2.CHECK UNLOCK SENSOR
Check unlock sensor.
Refer to DLK ...