Component Function Check
1.CHECK FUNCTION
Is the inspection result normal?
YES >> Shift P warning lamp is OK.
NO >> Refer to DLK "Diagnosis Procedure".
Diagnosis Procedure
1.CHECK SHIFT P WARNING LAMP
Refer to TM "Component Parts Function Inspection".
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace the malfunctioning parts.
2.CHECK INTERMITTENT INCIDENT
Refer to GI "Intermittent Incident".
>> Inspection End.

Component Function Check 1.CHECK FUNCTION Select INTELLIGENT KEY of BCM using CONSULT. Select TRUNK/GLASS HATCH in ACTIVE TEST mode. Touch OPEN to check that it works normally. Is the insp ...
P072C Stuck in 1GR
DTC Logic
DTC DETECTION LOGIC
DTC
Trouble diagnosis name
DTC detection condition
Possible causes
P072C
Stuck in Gear 1
The following diagnosis conditions
are met and the detection
conditions continue for 0.5 seconds
or more.- Diagnosis condition
- Shifti ...
Main power supply and ground circuit
Diagnosis Procedure
1.CHECK TCM POWER CIRCUIT (PART 1)
Turn ignition switch OFF.
Disconnect TCM connector.
Check voltage between TCM harness connector terminals and ground.
Is the inspection result normal?
YES >> GO TO 2.