Nissan Versa (N17): The low washer fluid warning continues displaying, or does not display

Nissan Versa 2nd generation (N17) Service Manual / Driver information & multimedia / Meter, warning lamp & indicator (MWI) / The low washer fluid warning continues displaying, or does not display

Description

  • The warning is still displayed even after washer fluid is added.
  • The warning is not displayed even though the washer tank is empty.

Diagnosis Procedure

1.CHECK WASHER FLUID LEVEL SWITCH

Perform a unit check for the washer fluid level switch. Refer to MWI "Component Inspection".

Is the inspection result normal?

YES >> GO TO 2

NO >> Replace washer fluid level switch. Refer to WW "Exploded View".

2.CHECK WASHER FLUID LEVEL SWITCH SIGNAL CIRCUIT

Check the washer fluid level switch signal circuit. Refer to MWI "Diagnosis Procedure".

Is the inspection result normal?

YES >> Replace combination meter. Refer to MWI "Removal and Installation".

NO >> Repair or replace harness or connector.

REMOVAL AND INSTALLATION

The oil pressure warning lamp does not turn on

Description The oil pressure warning lamp stays of when the ignition switch is turned ON. Diagnosis Procedure 1.CHECK COMBINATION METER OIL PRESSURE WARNING LIGHT 1. Select METER/M&A on CONS ...

Combination meter

Removal and Installation REMOVAL 1. Disconnect the negative battery terminal. Refer to PG "Removal and Installation". 2. Remove cluster lid A. Refer to IP "Removal and Installati ...

Other materials:

Input shaft and gear
Exploded View 1. Input shaft front bearing 2. Input shaft 3. Snap ring 4. Input shaft rear bearing 5. Adapter plate 6. Bushing 7. 5th input gear 8. 5th-reverse baulk ring 9. Synchronizer lever 10. 5th-reverse synchronizer hub 11. 5th-reverse coupling sleeve 12. Lock washer 13. Retaining pi ...

P0962 Pressure control solenoid A
DTC Logic DTC DETECTION LOGIC DTC Trouble diagnosis name DTC detection condition Possible causes P0962 Pressure Control Solenoid "A" Control Circuit Low The following diagnosis conditions are met, and the current monitor reading of the TCM line pressure s ...