Component Function Check
1.CHECK ABS WARNING LAMP FUNCTION
Check that ABS warning lamp in combination meter turns ON for approximately 2 seconds after ignition switch is turned ON.
Is the inspection result normal?
YES >> Inspection End.
NO >> Proceed to diagnosis procedure. Refer to BRC "Diagnosis Procedure".
Diagnosis Procedure
1.PERFORM THE SELF-DIAGNOSIS
With CONSULT.
Perform self diagnostic result.
Are any DTCs detected?
YES >> Refer to BRC "DTC Index".
NO >> GO TO 2.
2.CHECK COMBINATION METER
Check if indication and operation of combination meter are normal. Refer to MWI "METER SYSTEM : System Description" (type A) and MWI "METER SYSTEM : System Description" (type B).
Is the inspection result normal?
YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC "Removal and Installation".
NO >> Replace combination meter. Refer to MWI "Removal and Installation" (type A) or MWI "Removal and Installation" (type B).
 VDC OFF Switch
VDC OFF SwitchComponent Function Check 1.CHECK VDC OFF SWITCH OPERATION Check that VDC OFF indicator lamp in combination meter turns ON/OFF when VDC OFF switch is operated. Is the inspection result normal? ...
Remote keyless entry system (if so equipped)
   WARNING
	Radio waves could adversely affect
	electric medical equipment. Those who
	use a pacemaker should contact the
	electric medical equipment manufacturer
	for the possible influences before
	use.
	The remote keyless entry key fob transmits
	radio waves when the buttons are
	pressed. ...
   
A/T Control system
   A/T Control system : component parts location
1. IPDM E/R 2. TCM 3. Transmission range switch
4. A/T unit 5. Output speed sensor 6. Stop lamp switch
7. A/T shift selector 8. Overdrive control switch 9. Combination meter (type B)
A/T Control system : component description
	
		Name
		
		 ...