Diagnosis Procedure
1. CHECK DOOR MIRROR DEFOGGER FUSE
Check if the following fuse in fuse block (J/B) is blown.
Is the inspection result normal?
YES >> GO TO 2
NO >> If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse.
2. CHECK BOTH DOOR MIRROR DEFOGGER
1. Check door mirror LH. Refer to DEF "Component Function Check".
2. Check door mirror RH. Refer to DEF "Component Function Check".
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI "Intermittent Incident".
NO >> Repair or replace the malfunctioning parts.
DRIVER SIDE DOOR MIRROR DEFOGGER DOES NOT OPERATE
Diagnosis Procedure
1. CHECK DOOR MIRROR DEFOGGER LH
Check door mirror defogger LH.
Refer to DEF "Component Function Check".
Is the inspection result normal?
YES >> Refer to GI "Intermittent Incident".
NO >> Repair or replace the malfunctioning parts.
PASSENGER SIDE DOOR MIRROR DEFOGGER DOES NOT OPERATE
Diagnosis Procedure
1. CHECK DOOR MIRROR DEFOGGER RH
Check door mirror defogger RH.
Refer to DEF "Component Function Check".
Is the inspection result normal?
YES >> Refer to GI "Intermittent Incident".
NO >> Repair or replace the malfunctioning parts.
REAR WINDOW DEFOGGER SWITCH DOES NOT LIGHT, BUT REAR WINDOW DEFOGGER OPERATES
Diagnosis Procedure
1. CHECK FRONT AIR CONTROL (REAR WINDOW DEFOGGER SWITCH)
Check that the front air control (rear window defogger switch) is operating normally.
Is the inspection result normal?
YES >> Refer to GI "Intermittent Incident".
NO >> Refer to DEF "Diagnosis Procedure".
REMOVAL AND INSTALLATION
Rear window defogger and door
mirror defogger do not operateDiagnosis Procedure 1. CHECK REAR WINDOW DEFOGGER SWITCH Check rear window defogger switch. Refer to DEF "Component Function Check". Is the inspection result normal? YES >> GO ...

Inspection and Repair INSPECTION 1. When measuring voltage, wrap tin foil around the top of the negative probe. Then press the foil against the wire with your finger. 2. Attach probe circuit t ...
Power steering fluid
Check the fluid level in the reservoir.
The fluid level should be checked when the fluid
is cold at fluid temperatures of 32 to 86ºF (0 to
30ºC). The fluid level can be checked with the
level gauge which is attached to the cap. To
check the fluid level, remove the cap. The fluid ...
P1148 closed loop control
DTC Logic
DTC DETECTION LOGIC
NOTE:
DTC P1148 is displayed with DTC for A/F sensor 1.
When the DTC is detected, perform the trouble diagnosis of DTC corresponding to
A/F sensor 1.
DTC No.
Trouble diagnosis
(Trouble diagnosis content)
DTC detecting condition
Possible cause ...