DTC Logic

DTC DETECTION LOGIC   

DTC CONFIRMATION PROCEDURE

1.CHECK SELF DIAGNOSTIC RESULT

With CONSULT.

  1. Turn the ignition switch ON.
  2. Perform self diagnostic result.

Is DTC C1109 detected?

YES >> Proceed to diagnosis procedure. Refer to BRC "Diagnosis Procedure".

NO >> Inspection End.

Diagnosis Procedure

Regarding Wiring Diagram information, refer to BRC "Wiring Diagram".

1.CONNECTOR INSPECTION

  1. Turn ignition switch OFF.
  2. Disconnect ABS actuator and electric unit (control unit) connectors.
  3. Check connectors and terminals for deformation, disconnection, looseness or damage.

Is the inspection result normal?

YES >> GO TO 2

NO >> Repair or replace as necessary.

2.CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) IGNITION POWER SUPPLY CIRCUIT

Check voltage between ABS actuator and electric unit (control unit) connector E33 terminal 28 and ground.

Is the inspection result normal?

YES >> GO TO 3

NO >> Repair or replace malfunctioning components.

3.CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) GROUND CIRCUIT

  1. Turn ignition switch OFF.
  2. Check continuity between ABS actuator and electric unit (control unit) connector E33 terminals 13, 38 and ground.       

Is the inspection result normal?

YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC "Removal and Installation".

NO >> Repair or replace malfunctioning components.

C1110, C1153, C1170 ABS Actuator and electric unit (control unit)

DTC Logic DTC DETECTION LOGIC    DTC CONFIRMATION PROCEDURE 1.CHECK SELF-DIAGNOSIS RESULTS Check the self-diagnosis results.          ...

Other materials:

Power outlets
Instrument panel Console (if so equipped) The power outlets are for powering electrical accessories such as cellular telephones. The outlets are rated at 12 volt, 120W (10A) maximum. CAUTION The outlet and plug may be hot during or immediately after use. Only certain power outlets ...

Power steering fluid
Check the fluid level in the reservoir. The fluid level should be checked when the fluid is cold at fluid temperatures of 32 to 86ºF (0 to 30ºC). The fluid level can be checked with the level gauge which is attached to the cap. To check the fluid level, remove the cap. The fluid ...

Categories


© 2017-2026 Copyright www.niveguide.com
0.0066