DTC DETECTION LOGIC
| DTC | Trouble diagnosis name | DTC detection condition | Possible causes |
| P0740 | Torque Converter Clutch Circuit/ Open | The TCM torque converter clutch solenoid
valve current monitor reading is 200 mA or
less continuously for 5 seconds or more under
the following diagnosis conditions: - Diagnosis conditions - Solenoid valve output current: 750 mA or more - GND short diagnosis of the solenoid valve circuit is not satisfied. - TCM power supply voltage: More than 11 V |
- Harness or connector
(Torque converter clutch solenoid
valve circuit is open or shorted to power
supply) - Torque converter clutch solenoid valve |
DTC CONFIRMATION PROCEDURE
CAUTION: Be careful of the driving speed.
1.PREPARATION BEFORE OPERATION (PART 1)
If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition switch OFF and wait for at least 10 seconds, then perform the next test.
>> GO TO 2.
2.PREPARATION BEFORE OPERATION (PART 2)
With CONSULT
FLUID TEMP : 10C (50F) or more
With GST
NOTE: When the ambient temperature is 20C (68F), the CVT fluid usually increases to 50 to 80C (122 to 176F) with driving in an urban area for approximately 10 minutes.
Is the CVT fluid 10C (50F) or more?
YES >> GO TO 3.
NO >> 1. Warm the transaxle. 2. GO TO 3.
3.CHECK DTC DETECTION
Selector lever : "D" position
Vehicle speed : 40 km/h (25 MPH) or more
Is "P0740" detected?
YES >> Go to TM "Diagnosis Procedure".
NO >> INSPECTION END
1.CHECK CIRCUIT BETWEEN TCM AND CVT UNIT

Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace malfunctioning parts.
2.CHECK TORQUE CONVERTER CLUTCH SOLENOID VALVE
Check torque converter clutch solenoid valve. Refer to TM "Component Inspection (Torque Converter Clutch Solenoid Valve)".
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI "Intermittent Incident".
NO >> Repair or replace malfunctioning parts.
Component Inspection (Torque Converter Clutch Solenoid Valve)
1.CHECK TORQUE CONVERTER CLUTCH SOLENOID VALVE
Check resistance between CVT unit connector terminal and ground. 
Is the inspection result normal?
YES >> INSPECTION END
NO >> There is a malfunction of torque converter clutch solenoid valve. Replace transaxle assembly.
Refer to TM "Removal and Installation".
Engine assembly
Exploded View
1. Engine mounting (RH) stay 2. Engine mount (RH) stay 3. Engine mounting
insulator (RH)
4. Rear engine mounting bracket 5. Rear torque rod 6. Engine mounting bracket
(LH)
7. Engine mounting bracket (LH) 8. Engine mounting insulator (LH) 9. Mass damper
A. Front mark B. Tra ...
Additional service when replacing
ECM
Description
When replacing ECM, the following procedure must be performed.
PROGRAMMING OPERATION
NOTE:
After replacing with a blank ECM, programming is required to write ECM
information. Be sure to follow the procedure
to perform the programming.
Work Procedure
1.CHECK ECM PART NUMBER
Che ...