1.CHECK COOLING FAN FUNCTION
With CONSULT
NOTE: The cooling fan operates at high speeds even when "LOW" is selected in CONSULT "ACTIVE TEST". (For single connector cooling fan without A/C models)
Without CONSULT
Is the inspection result normal?
YES >> INSPECTION END
NO >> Refer to EC, "Diagnosis Procedure".
FOR SINGLE CONNECTOR COOLING FAN WITHOUT A/C MODELS
1.CHECK COOLING FAN MOTOR CIRCUIT
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
2.CHECK COOLING FAN MOTOR
Refer to EC, "Component Inspection (Cooling Fan Motor)".
Is the inspection result normal?
YES >> GO TO 3.
NO >> Replace cooling fan motor. Refer to CO, "Removal and Installation".
3.CHECK INTERMITTENT INCIDENT
Perform GI, "Intermittent Incident".
Is the inspection result normal?
YES >> Replace IPDM E/R. Refer to PCS, "Removal and Installation" (WITH I-KEY) or PCS, "Removal and Installation" (WITHOUT I-KEY).
NO >> Repair or replace harness or connector.
EXCEPT FOR SINGLE CONNECTOR COOLING FAN WITHOUT A/C MODELS
1.CHECK COOLING FAN MOTOR CIRCUIT
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
2.CHECK COOLING FAN RELAY CIRCUIT
Is the inspection result normal?
YES >> GO TO 3.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
3.CHECK COOLING FAN RELAY
Refer to EC, "Component Inspection (Cooling Fan Relay)".
YES or NO
YES >> GO TO 4.
NO >> Replace cooling fan relay.
4.CHECK COOLING FAN MOTOR
Refer to EC, "Component Inspection (Cooling Fan Motor)".
YES or NO
YES >> GO TO 5.
NO >> Replace cooling fan motor. Refer to CO, "Removal and Installation".
5.CHECK INTERMITTENT INCIDENT
Perform GI, "Intermittent Incident".
YES or NO
YES >> Replace IPDM E/R. Refer to PCS, "Removal and Installation" (WITH I-KEY) or PCS, "Removal and Installation" (WITHOUT I-KEY).
NO >> Repair or replace harness or connector.
1.CHECK COOLING FAN MOTOR
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace cooling fan motor. Refer to CO, "Removal and Installation".
Component Inspection (Cooling Fan Relay)
1.CHECK COOLING FAN RELAY
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace cooling fan relay.
Component Function Check 1.CHECK CLUTCH PEDAL POSITION SWITCH FUNCTION Turn ignition switch ON. Check the voltage between ECM harness connector and ground. Is the inspection result ...
Description The electrical load signal (Headlamp switch signal, rear window defogger switch signal, etc.) is transferred to ECM through the CAN communication line. ...
Air pressure monitor
AIR PRESSURE MONITOR : CONSULT Function
(BCM - AIR PRESSURE MONITOR)
NOTE:
The Signal Tech II Tool (J-50190) can be used to perform the following
functions. Refer to the Signal Tech II
User Guide for additional information.
Activate and display TPMS transmitter IDs
Display tire pressure ...
Shift P Warning lamp
Component Function Check
1.CHECK FUNCTION
Select INTELLIGENT KEY of BCM using CONSULT.
Select LCD in ACTIVE TEST mode.
Touch SET P to check that it works normally.
Is the inspection result normal?
YES >> Shift P warning lamp is OK.
NO >> Refer to DLK "Diagnosis Proce ...