Security indicator lamp does not blink when power supply position is other than the ON position.
NOTE:
Conditions of Vehicle (Operating Conditions) Power supply position is other than the ON position.
1.CHECK SECURITY INDICATOR LAMP
Check security indicator lamp.
Refer to DLK "Component Function Check".
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace the malfunctioning parts.
2.CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES >> Check intermittent incident. Refer to GI"Intermittent Incident".
NO >> GO TO 1.
REMOVAL AND INSTALLATION

Removal and Installation REMOVAL 1. Remove the instrument lower panel LH. Refer to IP"Removal and Installation". 2. Release the NATS antenna amp. pawls and remove NATS antenna amp. (1) ...
Consult function
APPLICATION ITEMS
Diagnostic test mode
Function
Work Support
This mode enables a technician to adjust some devices faster and
more accurately.
Self Diagnostic Results
Retrieve DTC from ECU and display diagnostic items.
Data Monitor
Monitor the input ...
P074B Unable to engage 3GR
Description
This malfunction is detected when the A/T does not shift into 3GR position as
instructed by TCM. This is not
only caused by electrical malfunction (circuits open or shorted) but by
mechanical malfunction such as control
valve sticking, improper solenoid valve operation, etc.
DTC ...