Description
Detects trunk open/close condition.
Component Function Check
1.CHECK FUNCTION
With CONSULT
Check TRNK/HAT MNTR in Data Monitor mode with CONSULT.
Is the inspection result normal?
YES >> Trunk room lamp switch is OK.
NO >> Refer to DLK "Diagnosis Procedure".
Regarding Wiring Diagram information, refer to DLK "INTELLIGENT KEY SYSTEM : Wiring Diagram".
1.CHECK TRUNK ROOM LAMP SWITCH INPUT SIGNAL
Is the inspection result normal?
YES >> GO TO 6
NO >> GO TO 2
2.CHECK TRUNK ROOM LAMP SWITCH CIRCUIT
Is the inspection result normal?
YES >> GO TO 3
NO >> Repair or replace harness between BCM and trunk room lamp switch.
3.CHECK TRUNK ROOM LAMP SWITCH GROUND CIRCUIT
Check continuity between trunk room lamp switch connector and ground.
Is the inspection result normal?
YES >> GO TO 4
NO >> Repair or replace trunk room lamp switch ground circuit.
4.CHECK BCM OUTPUT SIGNAL
Is the inspection result normal?
YES >> GO TO 5
NO >> Replace BCM. Refer to BCS "Removal and Installation".
5.CHECK TRUNK ROOM LAMP SWITCH
Refer to DLK "Component Inspection".
Is the inspection result normal?
YES >> GO TO 6
NO >> Replace trunk room lamp switch.
6.CHECK INTERMITTENT INCIDENT
Refer to GI "Intermittent Incident".
>> Inspection End.
1.CHECK TRUNK ROOM LAMP SWITCH
Is the inspection result normal?
YES >> Inspection End.
NO >> Replace trunk room lamp switch.
SYMPTOM DIAGNOSIS
Remote keyless entry system (if so equipped)
WARNING
Radio waves could adversely affect
electric medical equipment. Those who
use a pacemaker should contact the
electric medical equipment manufacturer
for the possible influences before
use.
The remote keyless entry key fob transmits
radio waves when the buttons are
pressed. ...
Compressor does not operate
Description
SYMPTOM
Compressor does not operate.
Diagnosis Procedure
NOTE:
Perform self-diagnosis with CONSULT before performing symptom
diagnosis. If any malfunction result or
DTC is detected, perform the corresponding diagnosis.
Check that refrigerant system is fully charged. If t ...