Description
Performs operation method guide and warning with buzzer.
1.CHECK FUNCTION
With CONSULT
Is the inspection result normal?
YES >> Warning buzzer into combination meter is OK.
NO >> Refer to DLK "Diagnosis Procedure".
1.CHECK METER BUZZER CIRCUIT
Operate the hazard lights by turning ON the hazard warning switch.
Is the inspection result normal?
YES >> GO TO 2
NO >> Replace combination meter. Refer to MWI "Removal and Installation" (type B) or MWI "Removal and Installation" (type A).
2.CHECK INTERMITTENT INCIDENT
Refer to GI "Intermittent Incident".
>> Inspection End.
Horn functionDescription Perform answer-back for each operation with horn. ...

Description Perform answer-back for each operation with number of blinks. Component Function Check 1.CHECK FUNCTION Check hazard warning lamp ("FLASHER") in Active Test. Is the inspection resul ...
Insufficient heating
Description
Symptom
Insufficient heating
No warm air comes out. (Air flow volume is normal.)
Diagnosis Procedure
NOTE:
Perform self-diagnosis with CONSULT before performing symptom diagnosis. If any
malfunction result or DTC
is detected, perform the corresponding diagnosis.
1.CHECK ...
Remote keyless entry receiver
Removal and Installation
REMOVAL
1. Remove the glove box. Refer to IP "Removal and Installation".
2. Remove the remote keyless entry receiver bolt (A).
3. Disconnect the harness connector from remote keyless entry
receiver and remove remote keyless entry receiver (1)
INSTALLATION ...