Description
Performs operation method guide and warning with buzzer.
1.CHECK FUNCTION
With CONSULT
Is the inspection result normal?
YES >> Warning buzzer into combination meter is OK.
NO >> Refer to DLK "Diagnosis Procedure".
1.CHECK METER BUZZER CIRCUIT
Operate the hazard lights by turning ON the hazard warning switch.
Is the inspection result normal?
YES >> GO TO 2
NO >> Replace combination meter. Refer to MWI "Removal and Installation" (type B) or MWI "Removal and Installation" (type A).
2.CHECK INTERMITTENT INCIDENT
Refer to GI "Intermittent Incident".
>> Inspection End.
Horn functionDescription Perform answer-back for each operation with horn. ...

Description Perform answer-back for each operation with number of blinks. Component Function Check 1.CHECK FUNCTION Check hazard warning lamp ("FLASHER") in Active Test. Is the inspection resul ...
A/T Fluid cooler
Cleaning
Whenever the A/T is repaired, overhauled, or replaced, the A/T fluid cooler
mounted in the radiator must be
inspected and cleaned.
Metal debris and friction material, if present, can become trapped in the A/T
fluid cooler. This debris can contaminate
the newly serviced A/T or, i ...
P0846 Transmission fluid pressure
SEN/SW B
DTC Logic
DTC DETECTION LOGIC
DTC
Trouble diagnosis name
DTC detection condition
Possible causes
P0846
Transmission Fluid Pressure
Sensor/Switch B Circuit
Range/Performance
The detection conditions continuously for 5
seconds or more under the following diagn ...