Component Function Check
1.CHECK FUNCTION
Is the inspection result normal?
Yes >> Combination meter buzzer is OK.
No >> Refer to DLK "Diagnosis Procedure".
Diagnosis Procedure
1.CHECK METER BUZZER CIRCUIT
Refer to WCS "Component Function Check".
Is the inspection result normal?
Yes >> GO TO 2.
No >> Repair or replace harness.
2.CHECK INTERMITTENT INCIDENT
Refer to GI "Intermittent Incident".
>> Inspection End.
Power supply and ground circuitDiagnosis Procedure Regarding Wiring Diagram information, refer to BCS "Wiring Diagram". 1.CHECK FUSES AND FUSIBLE LINK Check that the following fuses and fusible link are not blown.&nb ...
P0983 Shift solenoid D
DTC Logic
DTC DETECTION LOGIC
DTC
Trouble diagnosis name
DTC detection condition
Possible causes
P0983
Shift Solenoid D Control Circuit
High
The following diagnosis conditions
are met, and the current
monitor reading of the TCM line
pressure solenoid val ...
P0711 Transmission fluid temperature
sensor A
DTC Logic
DTC DETECTION LOGIC
DTC
Trouble diagnosis name
DTC detection condition
Possible causes
P0711
Transmission Fluid Temperature
Sensor A Circuit Range/
Performance
Under the following diagnosis conditions, CVT
fluid temperature does not rise to 10C (5 ...