NOTE: The Signal Tech II Tool (J-50190) can be used to perform the following functions. Refer to the Signal Tech II User Guide for additional information.
1.CHECK FUNCTION

Is the inspection result normal? YES >> Intelligent Key is OK.
NO >> Refer to DLK-93, "Diagnosis Procedure".
NOTE: The Signal Tech II Tool (J-50190) can be used to perform the following functions. Refer to the Signal Tech II User Guide for additional information.
1.CHECK INTELLIGENT KEY BATTERY
Check by connecting a resistance (approximately 300Ω) so that the current value becomes about 10 mA. Refer to DLK "Removal and Installation".
Standard : Approx. 2.5 - 3.0V
Is the measurement value within the specification?
YES >> Replace Intelligent Key.
NO >> Replace Intelligent Key battery.

Hazard functionComponent Function Check 1.CHECK FUNCTION Select INTELLIGENT KEY of BCM using CONSULT. Select FLASHER in ACTIVE TEST mode. Touch LH or RH to check that it works normally. Is the inspecti ...

Component Function Check 1.CHECK FUNCTION Select INTELLIGENT KEY of BCM using CONSULT. Select INDICATOR in ACTIVE TEST mode. Touch KEY IND or KEY ON to check that it works normally. Is the ...
EVAP canister filter
Exploded View
1. EVAP canister vent control valve hose 2. Canister drain hose 3. EVAP
canister filter
Front
Removal and Installation
REMOVAL
Remove the EVAP canister protector cover.
Disconnect EVAP canister vent control valve hose from EVAP canister
filter.
Disconnect caniste ...
5Th main gear assembly
Removal and Installation
REMOVAL
Move the shift selector to the 3rd gear position.
Disconnect the shifter cable and the selector cable from shifter lever A
and selector lever. Refer to TM,
"Removal and Installation".
CAUTION:
Do not move shifter lever A and selector leve ...