Description
The starter motor magnetic switch is supplied with power when the ignition switch is turned to the START position while the selector lever is in the P (Park) or N (Neutral) position.
Diagnosis Procedure
Regarding Wiring Diagram information, refer to STR, "Wiring Diagram - With Intelligent Key System" or STR, "Wiring Diagram - Without Intelligent Key System".
CAUTION: Perform diagnosis under the condition that engine cannot start by the following procedure.
1.CHECK "S" CONNECTOR CIRCUIT

Is the inspection result normal?
YES >> "S" circuit is OK. Further inspection is necessary. Refer to STR, "Work Flow (With GR8-1200 NI)" or STR, "Work Flow (Without GR8-1200 NI)".
NO >> GO TO 2.
2.CHECK HARNESS CONTINUITY (OPEN CIRCUIT)


Is the inspection result normal?
YES >> Further inspection is necessary. Refer to STR, "Work Flow (With GR8-1200 NI)" or STR, "Work Flow (Without GR8-1200 NI)".
NO >> Repair or replace the harness or connectors.
STARTING SYSTEM
Symptom Table
| Symptom | Reference |
| No normal cranking | Refer to STR, "Work Flow (With GR8-1200 NI)" or STR, "Work Flow (Without GR8-1200 NI)". |
| Starter motor does not rotate |
B terminal circuitDescription Terminal "B" is constantly supplied with battery power. Diagnosis Procedure Regarding Wiring Diagram information, refer to STR, "Wiring Diagram - With Intelligent Key System&quo ...
P0863 TCM Communication
DTC Logic
DTC DETECTION LOGIC
DTC
Trouble diagnosis name
DTC detection condition
Possible causes
P0863
TCM Communication Circui
An error is detected at the initial CAN diagnosis
of TCM.
TCM
DTC CONFIRMATION PROCEDURE
1.PREPARATION BEFORE WORK
If anothe ...
Precautions
Precaution for Supplemental Restraint System
(SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER"
The Supplemental Restraint System such as "AIR BAG" and "SEAT BELT
PRE-TENSIONER", used along
with a front seat belt, helps to reduce the risk or severity of injury to the
driver and ...