AIR BAG Warning Lamp Does Not Turn Off
1.CHECK CONDITION OF AIR BAG MODULE
Inspect for any deployed air bag modules or seat belt pre-tensioners.
Are any air bag modules or seat belt pre-tensioners deployed?
YES >> Refer to SR "For Frontal Collision" or SR "For Side and Rollover Collision".
NO >> GO TO 2
2.CHECK THE AIR BAG FUSE
Check 10A fuse [No. 7, located in the fuse block (J/B)].
Is the fuse blown?
YES >> GO TO 3
NO >> GO TO 4
3.CHECK AIR BAG FUSE AGAIN
Replace 10A fuse [No. 7, located in the fuse block (J/B)] and turn ignition switch ON.
Does the fuse blow again?
YES >> Replace fuse and harness.
NO >> Inspection End.
4.CHECK AIR BAG DIAGNOSIS SENSOR UNIT
Connect CONSULT.
Is "AIR BAG" displayed on CONSULT?
YES >> GO TO 5
NO >> Visually inspect the air bag diagnosis sensor unit harness connections. If the connections are OK, replace the air bag diagnosis sensor unit. Refer to SR "Removal and Installation".
5.CHECK HARNESS CONNECTION
Check for loose connections between the combination meter and the air bag diagnosis sensor unit.
Are there any loose connections?
YES >> Properly connect the combination meter and air bag diagnosis sensor unit harness connectors. If AIR BAG warning lamp still does not turn off, replace the wiring harness.
NO >> Replace air bag diagnosis sensor unit. Refer to SR "Removal and Installation".
SRS Air bag warning lamp does not
turn onAIR BAG Warning Lamp Does Not Turn On 1.CHECK METER FUSE Check the 10A fuse [No. 3, located in the fuse block (J/B)]. Is the fuse blown? YES >> GO TO 2 NO >> GO TO 3 2.REPLACE METER ...

Seat Belt Warning System Does Not Function 1.SEAT BELT WARNING LIGHT Turn ignition switch ON. Does the seat belt warning lamp come ON? YES >> GO TO 2 NO >> Check 10A fuse [No. 3, ...
P0713 Transmission fluid temperature
sensor A
DTC Logic
DTC DETECTION LOGIC
DTC
Trouble diagnosis name
DTC detection condition
Possible causes
P0713
Transmission Fluid Temperature
Sensor "A" Circuit High
Under the following diagnosis
conditions, the A/T fluid temperature
identified by TCM is −
...
P0732 2GR Incorrect ratio
Description
This malfunction is detected when the A/T does not shift into 2GR position as
instructed by TCM. This is not
only caused by electrical malfunction (circuits open or shorted) but by
mechanical malfunction such as control
valve sticking, improper solenoid valve operation, etc.
DTC ...