Description

The ignition relay integrated in IPDM E/R is operated with ignition switch ON signal from the ignition switch.

DTC Logic

DTC DETECTION LOGIC

Diagnosis Procedure

1. PERFORM SELF DIAGNOSTIC RESULT

1. Turn the ignition switch ON.

2. Erase "SELF-DIAG RESULTS" of IPDM E/R.

3. Turn ignition switch OFF, and wait for 1 second or more.

4. Turn the ignition switch ON. Check "SELF-DIAG RESULTS" again.

Is "IGN RELAY ON" displayed?

YES >> Replace IPDM E/R. Refer to PCS "Removal and Installation".

NO >> Refer to GI "Intermittent Incident".

B2098 Ignition relay on stuck

Description The ignition relay integrated in IPDM E/R is operated with ignition switch ON signal from the ignition switch. DTC Logic DTC DETECTION LOGIC Diagnosis Procedure 1. PERFORM SELF ...

Power supply and ground circuit

Diagnosis Procedure Regarding Wiring Diagram information, refer to PCS "Wiring Diagram". 1. CHECK FUSE AND FUSIBLE LINKS Check that the following IPDM E/R fuse or fusible links are not bl ...