BACK-UP LAMP SWITCH : Component Inspection
1.CHECK BACK-UP LAMP SWITCH
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace position switch. Refer to TM, "Removal and Installation".
PARK/NEUTRAL POSITION (PNP) SWITCH : Component Inspection
1.CHECK PARK/NEUTRAL POSITION (PNP) SWITCH
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace position switch. Refer to TM, "Removal and Installation".
NOISE, VIBRATION AND HARSHNESS (NVH) TROUBLESHOOTING
NVH Troubleshooting Chart
Use the chart below to find the cause of the symptom. The numbers indicate the order of the inspection. If necessary, repair or replace these parts.
Sectional View 1. Clutch housing 2. 1st-2nd synchronizer hub assembly 3. 3rd-4th synchronizer hub assembly 4. 5th input gear 5. 5th-reverse synchronizer hub assembly 6. 5th-reverse baulk ri ...
Inspection OIL LEAKAGE Make sure that gear oil is not leaking from transaxle or around it. OIL LEVEL Remove filler plug (1) and gasket from transaxle case. Check the oil level from filler pl ...
P0743 Torque converter
DTC Logic
DTC DETECTION LOGIC
DTC
Trouble diagnosis name
DTC detection condition
Possible causes
P0743
Torque Converter Clutch Circuit
Electrical
The following diagnosis conditions
are met, and the TCM
torque converter clutch solenoid
valve current monito ...
VDC OFF Indicator lamp
Component Function Check
1.CHECK VDC OFF INDICATOR LAMP FUNCTION
Check that VDC OFF indicator lamp in combination meter turns ON for
approximately 2 seconds after ignition
switch is turned ON.
Is the inspection result normal?
YES >> Inspection End.
NO >> Proceed to diagnosis pr ...