Exploded View

1. Map lamp bulb housing 2. Bulb 3. Lens
Pawl
WARNING: Do not touch bulb with your hand while it is on or right after being turned off. Burning may result.
CAUTION: Do not touch the glass surface of the bulb with bare hands or allow oil or grease to get on it to prevent damage to the bulb.
REMOVAL
1. Release lens pawls using suitable tool (A) and remove.
CAUTION: Apply protect tape (B) on suitable tool (A).
: Pawl

2. Release map lamp housing pawl using suitable tool (A).
CAUTION: Apply protect tape (B) on suitable tool (A).
: Pawl
3. Disconnect the harness connector from map lamp and remove.

INSTALLATION
Installation is in the reverse order of removal.
WARNING: Do not touch bulb with your hand while it is on or right after being turned off. Burning may result.
CAUTION:
MAP LAMP BULB
Removal
1. Release lens pawls using suitable tool (A) and remove.
CAUTION: Apply protect tape (B) on suitable tool (A).
Pawl

2. Remove the bulb.
Installation
Installation is in the reverse order of removal.
Push-button ignition switch illumination
circuitDescription Provides the power supply and the ground to control the push-button ignition switch illumination. ...
EVAP canister vent control valve
Exploded View
1. EVAP canister 2. O-ring 3. EVAP canister vent control valve
4. EVAP canister vent control valve hose
Removal and Installation
NOTE:
The EVAP canister vent control valve can be removed without removing the EVAP
canister.
REMOVAL
Remove the EVAP canister protector cov ...
P0713 Transmission fluid temperature
sensor A
DTC Logic
DTC DETECTION LOGIC
DTC
Trouble diagnosis name
DTC detection condition
Possible causes
P0713
Transmission Fluid Temperature
Sensor "A" Circuit High
Under the following diagnosis
conditions, the A/T fluid temperature
identified by TCM is −
...