1.CHECK FRONT WIPER LO OPERATION
IPDM E/R AUTO ACTIVE TEST
1. Start IPDM E/R auto active test. Refer to PCS "Diagnosis Description" or PCS "Diagnosis Description".
2. Check that the front wiper operates on LO operation.
CONSULT ACTIVE TEST
1. Select FR WIPER of BCM (WIPER) active test item.
2. Check front wiper operation.
LO : Front wiper (LO) operation
OFF : Front wiper OFF
Is the inspection result normal?
YES >> Front wiper motor LO circuit is normal.
NO >> Refer to WW "Diagnosis Procedure".
Regarding Wiring Diagram information, refer to WW "Wiring Diagram".
1. CHECK FRONT WIPER MOTOR FUSE
1. Turn the ignition switch OFF.
2. Check that the following fuse is not blown.
Is the fuse blown?
YES >> Replace the fuse after repairing the affected circuit.
NO >> GO TO 2
2. CHECK FRONT WIPER MOTOR (LO) OUTPUT VOLTAGE
1. Turn the ignition switch ON.
2. Select FR WIPER of BCM (WIPER) active test item.
3. While performing the active test, check voltage between IPDM E/R harness
connector and ground.
Is the inspection result normal?
YES >> GO TO 3
NO >> Replace IPDM E/R. Refer to PCS "Removal and Installation".
3. CHECK FRONT WIPER MOTOR (LO) OPEN CIRCUIT
1. Turn the ignition switch OFF.
2. Disconnect IPDM E/R and front wiper motor.
3. Check continuity between IPDM E/R harness connector and front wiper motor
harness connector.
Is the inspection result normal?
YES >> Replace front wiper motor. Refer to WW "WIPER DRIVE ASSEMBLY : Removal and Installation".
NO >> Repair or replace harness.
Wiper and washer fuseDescription Diagnosis Procedure 1. CHECK FUSES Check that the following fuses are not blown. Is the f ...
Air breather hose
Removal and Installation
REMOVAL
Remove air duct (inlet). Refer to EM "Exploded View".
Remove air breather hose from transaxle assembly.
INSTALLATION
Installation is in the reverse order of removal.
CAUTION:
Check that air breather hose is not collapsed or blocked due to ...
Crash zone sensor
Exploded View
1. Crash zone sensor 2. Bracket A. Nut
Front
Removal and Installation
REMOVAL
WARNING:
Before servicing, turn ignition switch OFF, disconnect battery
negative terminal and wait three minutes
or more.
Do not use the air tools or electric tools for servicing.
CAU ...