Nissan Versa (N17): C1116 Stop lamp switch

DTC Logic

DTC DETECTION LOGIC       

DTC CONFIRMATION PROCEDURE

1.CHECK SELF-DIAGNOSIS RESULTS

Check the self-diagnosis results.                                       

Is above displayed on the self-diagnosis display?

YES >> Proceed to diagnosis procedure. Refer to BRC "Diagnosis Procedure".

NO >> Inspection End.

Diagnosis Procedure

Regarding Wiring Diagram information, refer to BRC "Wiring Diagram".

1.CONNECTOR INSPECTION

  1. Disconnect stop lamp switch connector and ABS actuator and electric unit (control unit) connector.
  2. Check terminals for deformation, disconnection, looseness or damage.

Is the inspection result normal?

YES >> GO TO 2

NO >> Repair or replace as necessary.

2.CHECK STOP LAMP SWITCH CIRCUIT

  1. Connect stop lamp switch connector.
  2. Check voltage between ABS actuator and electric unit (control unit) connector E33 terminal 30 and ground.       

Is the inspection result normal?

YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC "Removal and Installation".

NO >> GO TO 3

3.CHECK STOP LAMP SWITCH CIRCUIT FOR OPEN

  1. Disconnect stop lamp switch connector.
  2. Check continuity between ABS actuator and electric unit (control unit) connector E33 terminal 30 and stop lamp switch connector E13 (with CVT) or E57 (with M/T) terminal 2.       

Is the inspection result normal?

YES >> GO TO 4.

NO >> Repair or replace as necessary.

4.CHECK STOP LAMP SWITCH CIRCUIT FOR SHORT

Check continuity between ABS actuator and electric unit (control unit) connector E33 terminal 30 and ground.

Is the inspection result normal?

YES >> Replace stop lamp switch.

NO >> Repair harness or connectors.

Other materials:

P0983 Shift solenoid D
DTC Logic DTC DETECTION LOGIC DTC Trouble diagnosis name DTC detection condition Possible causes P0983 Shift Solenoid D Control Circuit High The following diagnosis conditions are met, and the current monitor reading of the TCM line pressure solenoid val ...

Expansion valve
Removal and Installation CAUTION: Perform oil return operation before each refrigeration system disassembly. However, if a large amount of refrigerant or oil is detected, do not perform oil return operation. Refer to HA "Perform Oil Return Operation". REMOVAL Use refrigerant c ...

Categories


© 2017-2025 Copyright www.niveguide.com