Nissan Versa (N17): Insufficient heating

Nissan Versa 2nd generation (N17) Service Manual / Ventilation, heater & air conditioner / Heater & air conditioning control system (HAC) / Insufficient heating

Description

Symptom

  • Insufficient heating
  • No warm air comes out. (Air flow volume is normal.)

Diagnosis Procedure

NOTE: Perform self-diagnosis with CONSULT before performing symptom diagnosis. If any malfunction result or DTC is detected, perform the corresponding diagnosis.

1.CHECK COOLING SYSTEM

  1. Check engine coolant level and check for leakage. Refer to CO "Inspection".
  2. Check radiator cap. Refer to CO "RADIATOR CAP : Inspection".
  3. Check water flow sounds of the engine coolant. Refer to CO "Refilling Engine Coolant".

Is the inspection result normal?

YES >> GO TO 2.

NO >> Refill engine coolant and repair or replace the parts depending on the inspection results.

2.CHECK HEATER HOSE

Check installation of heater hose by visually or touching.

Is the inspection result normal?

YES >> GO TO 3.

NO >> Repair or replace parts depending on the inspection results.

3.CHECK HEATER CORE

  1. Check temperature of inlet hose and outlet hose of heater core.
  2. Check that inlet side of heater core is hot and the outlet side is slightly lower than/almost equal to the inlet side.

CAUTION: Always perform the temperature inspection in a short period of time because the engine coolant temperature is very hot.

Is the inspection result normal?

YES >> GO TO 4.

NO >> Replace heater core. Refer to HA "Removal and Installation".

4.CHECK AIR LEAKAGE FROM EACH DUCT

Check duct and nozzle, etc. of air conditioning system for air leakage.

Is the inspection result normal?

YES >> Check air mix door cable installation and air mix door operation.

NO >> Repair or replace parts depending on the inspection results.

Insufficient cooling

Description Symptom Insufficient cooling No cool air comes out. (Air flow volume is normal.) Diagnosis Procedure NOTE: Perform self-diagnosis with CONSULT before performing symptom dia ...

Compressor does not operate

Description SYMPTOM Compressor does not operate. Diagnosis Procedure NOTE: Perform self-diagnosis with CONSULT before performing symptom diagnosis. If any malfunction result or DTC is d ...

Other materials:

Mixture ratio selflearning value clear
Description This describes how to erase the mixture ratio selflearning value. For the actual procedure, follow the instructions in "Diagnosis Procedure". Work Procedure 1.START With CONSULT Start engine and warm it up to normal operating temperature. Select "SELFLEARNING CONT" in "WOR ...

Fuel level sensor unit
Disassembly and Assembly Fuel Level Sender Unit 1. Harness connectors 2. Level sending unit module 3. Fuel temperature sensor 4. Float arm assembly Disassembly NOTE: Before disassembly, note the proper placement of the wires to the correct terminals and correct wire routing to the term ...