Nissan Versa (N17): Insufficient heating

Nissan Versa 2nd generation (N17) Service Manual / Ventilation, heater & air conditioner / Heater & air conditioning control system (HAC) / Insufficient heating

Description

Symptom

  • Insufficient heating
  • No warm air comes out. (Air flow volume is normal.)

Diagnosis Procedure

NOTE: Perform self-diagnosis with CONSULT before performing symptom diagnosis. If any malfunction result or DTC is detected, perform the corresponding diagnosis.

1.CHECK COOLING SYSTEM

  1. Check engine coolant level and check for leakage. Refer to CO "Inspection".
  2. Check radiator cap. Refer to CO "RADIATOR CAP : Inspection".
  3. Check water flow sounds of the engine coolant. Refer to CO "Refilling Engine Coolant".

Is the inspection result normal?

YES >> GO TO 2.

NO >> Refill engine coolant and repair or replace the parts depending on the inspection results.

2.CHECK HEATER HOSE

Check installation of heater hose by visually or touching.

Is the inspection result normal?

YES >> GO TO 3.

NO >> Repair or replace parts depending on the inspection results.

3.CHECK HEATER CORE

  1. Check temperature of inlet hose and outlet hose of heater core.
  2. Check that inlet side of heater core is hot and the outlet side is slightly lower than/almost equal to the inlet side.

CAUTION: Always perform the temperature inspection in a short period of time because the engine coolant temperature is very hot.

Is the inspection result normal?

YES >> GO TO 4.

NO >> Replace heater core. Refer to HA "Removal and Installation".

4.CHECK AIR LEAKAGE FROM EACH DUCT

Check duct and nozzle, etc. of air conditioning system for air leakage.

Is the inspection result normal?

YES >> Check air mix door cable installation and air mix door operation.

NO >> Repair or replace parts depending on the inspection results.

Insufficient cooling

Description Symptom Insufficient cooling No cool air comes out. (Air flow volume is normal.) Diagnosis Procedure NOTE: Perform self-diagnosis with CONSULT before performing symptom dia ...

Compressor does not operate

Description SYMPTOM Compressor does not operate. Diagnosis Procedure NOTE: Perform self-diagnosis with CONSULT before performing symptom diagnosis. If any malfunction result or DTC is d ...

Other materials:

P0962 Pressure control solenoid A
DTC Logic DTC DETECTION LOGIC DTC Trouble diagnosis name DTC detection condition Possible causes P0962 Pressure Control Solenoid "A" Control Circuit Low The following diagnosis conditions are met, and the current monitor reading of the TCM line pressure s ...

Line pressure control
LINE PRESSURE CONTROL : System Description SYSTEM DIAGRAM DESCRIPTION Highly accurate line pressure control (secondary pressure control) reduces friction for improvement of fuel economy. Normal Oil Pressure Control Appropriate line pressure and secondary pressure suitable for driving c ...