Nissan Versa (N17): Insufficient cooling

Nissan Versa 2nd generation (N17) Service Manual / Ventilation, heater & air conditioner / Heater & air conditioning control system (HAC) / Insufficient cooling

Description

Symptom

  • Insufficient cooling
  • No cool air comes out. (Air flow volume is normal.)

Diagnosis Procedure

NOTE: Perform self-diagnosis with CONSULT before performing symptom diagnosis. If any malfunction result or DTC is detected, perform the corresponding diagnosis.

1.CHECK MAGNET CLUTCH OPERATION

  1. Turn ignition switch ON.
  2. Turn fan control dial ON.
  3. Press A/C switch.
  4. Check that A/C indicator turns ON. Check visually and by sound that compressor operates.
  5. Press A/C switch again.
  6. Check that A/C indicator turns OFF. Check that compressor stops.

Is the inspection result normal?

YES >> GO TO 2.

NO >> Check compressor operation. Refer to HAC "Diagnosis Procedure".

2.CHECK DRIVE BELT

Check tension of drive belt. Refer to EM "Inspection".

Is the inspection result normal?

YES >> GO TO 3.

NO >> Adjust or replace drive belt depending on the inspection results.

3.CHECK REFRIGERANT CYCLE PRESSURE

Connect the recovery/recycling recharging equipment to the vehicle and perform the pressure inspection using gauge. Refer to HA "Symptom Table".

Is the inspection result normal?

YES >> GO TO 4.

NO >> Repair or replace parts depending on the inspection results.

4.CHECK AIR LEAKAGE FROM EACH DUCT

Check duct and nozzle, etc. of the air conditioner system for leakage.

Is the inspection result normal?

YES >> Check air mix door cable installation and air mix door operation.

NO >> Repair or replace parts depending on the inspection results.

Insufficient heating

Description Symptom Insufficient heating No warm air comes out. (Air flow volume is normal.) Diagnosis Procedure NOTE: Perform self-diagnosis with CONSULT before performing symptom diagn ...

Other materials:

EVAP canister vent control valve
Exploded View 1. EVAP canister 2. O-ring 3. EVAP canister vent control valve 4. EVAP canister vent control valve hose Removal and Installation NOTE: The EVAP canister vent control valve can be removed without removing the EVAP canister. REMOVAL Remove the EVAP canister protector cov ...

Additional service when replacing TCM
Description Always perform the following items when the TCM is replaced. LOADING OF THE CALIBRATION DATA The TCM acquires calibration data (individual characteristic value) of each solenoid that is stored in the ROM assembly (in the control valve). This enables the TCM to perform accur ...

Categories


© 2017-2025 Copyright www.niveguide.com
0.0074