DTC DETECTION LOGIC
DTC No. | Trouble diagnosis | DTC detecting condition | Possible cause |
P1554 | Battery current sensor performance | The output voltage of the battery current sensor is lower than the specified value while the battery voltage is high enough. |
|
DTC CONFIRMATION PROCEDURE
1.PERFORM COMPONENT FUNCTION CHECK
Perform component function check. Refer to EC, "Component Function Check".
NOTE: Use component function check to check the overall function of the battery current sensor circuit. During this check, a 1st trip DTC might not be confirmed.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Go to EC, "Diagnosis Procedure".
1.PRECONDITIONING
TESTING CONDITION:
>> GO TO 2.
2.PERFORM COMPONENT FUNCTION CHECK
With CONSULT
"BAT CUR SEN" should be above 2,300 mV at least once.
Without CONSULT
Is the inspection result normal?
YES >> INSPECTION END
NO >> Go to EC, "Diagnosis Procedure"
1.CHECK GROUND CONNECTION
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace ground connection.
2.CHECK BATTERY CURRENT SENSOR POWER SUPPLY
Is the inspection result normal?
YES >> GO TO 4.
NO >> GO TO 3.
3.CHECK BATTERY CURRENT SENSOR POWER SUPPLY CIRCUIT
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI, "Intermittent Incident".
NO >> Repair or replace error-detected parts.
4.CHECK BATTERY CURRENT SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
Is the inspection result normal?
YES >> GO TO 5.
NO >> Repair or replace error-detected parts.
5.CHECK BATTERY CURRENT SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
Is the inspection result normal?
YES >> GO TO 6.
NO >> Repair or replace error-detected parts.
6.CHECK BATTERY CURRENT SENSOR
Check battery current sensor. Refer to EC, "Component Inspection".
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI, "Intermittent Incident".
NO >> Replace battery negative cable assembly.
1.CHECK BATTERY CURRENT SENSOR
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace battery negative cable assembly.
VDC OFF Indicator lamp
Component Function Check
1.CHECK VDC OFF INDICATOR LAMP FUNCTION
Check that VDC OFF indicator lamp in combination meter turns ON for
approximately 2 seconds after ignition
switch is turned ON.
Is the inspection result normal?
YES >> Inspection End.
NO >> Proceed to diagnosis pr ...
Hazard and buzzer reminder does
not operate
Diagnosis Procedure
1.CHECK HAZARD ANSWER BACK SETTING IN WORK SUPPORT
Select INTELLIGENT KEY of BCM using CONSULT.
Select HAZARD ANSWER BACK in WORK SUPPORT mode.
Check the HAZARD ANSWER BACK setting in WORK SUPPORT.
Refer to BCS "INTELLIGENT KEY : CONSULT Function (BCM - INTELLIG ...