Component Function Check
1.CHECK SLIP INDICATOR LAMP FUNCTION
Check that slip indicator lamp in combination meter turns ON for approximately 2 seconds after ignition switch is turned ON.
Is the inspection result normal?
YES >> Inspection End.
NO >> Proceed to diagnosis procedure. Refer to BRC "Diagnosis Procedure".
Diagnosis Procedure
1.PERFORM THE SELF-DIAGNOSIS
With CONSULT.
Perform self diagnostic result.
Are any DTCs detected?
YES >> Refer to BRC "DTC Index".
NO >> GO TO 2.
2.CHECK COMBINATION METER
Check if indication and operation of combination meter are normal. Refer to MWI "METER SYSTEM : System Description" (type A) and MWI "METER SYSTEM : System Description" (type B).
Is the inspection result normal?
YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC "Removal and Installation".
NO >> Replace combination meter. Refer to MWI "Removal and Installation" (type A) or MWI "Removal and Installation" (type B).
SYMPTOM DIAGNOSIS
VDC OFF Indicator lampComponent Function Check 1.CHECK VDC OFF INDICATOR LAMP FUNCTION Check that VDC OFF indicator lamp in combination meter turns ON for approximately 2 seconds after ignition switch is turned ON. ...

Symptom Table If ABS warning lamp and SLIP indicator lamp turn ON, perform self-diagnosis. NOTE: The ABS does not operate when the speed is 10 km/h (6 MPH) or less. Under the following con ...
Fuel filler cap warning system
FUEL FILLER CAP WARNING SYSTEM : System Diagram
FUEL FILLER CAP WARNING SYSTEM : System Description
INPUT/OUTPUT SIGNAL CHART
Input
Unit/Sensor
Input signal to ECM
ECM function
EVAP control system pressure sensor
Pressure in purge line
Fuel filler cap warning cont ...
P0731 1GR Incorrect ratio
Description
This malfunction is detected when the A/T does not shift into 1GR position as
instructed by TCM. This is not
only caused by electrical malfunction (circuits open or shorted) but by
mechanical malfunction such as control
valve sticking, improper solenoid valve operation, etc.
DTC ...