Component Function Check
1.CHECK VDC OFF INDICATOR LAMP FUNCTION
Check that VDC OFF indicator lamp in combination meter turns ON for approximately 2 seconds after ignition switch is turned ON.
Is the inspection result normal?
YES >> Inspection End.
NO >> Proceed to diagnosis procedure. Refer to BRC "Diagnosis Procedure".
Diagnosis Procedure
1.PERFORM THE SELF-DIAGNOSIS
With CONSULT.
Perform self diagnostic result.
Are any DTCs detected?
YES >> Refer to BRC "DTC Index".
NO >> GO TO 2.
2.CHECK COMBINATION METER
Check if indication and operation of combination meter are normal. Refer to MWI "METER SYSTEM : System Description" (type A) and MWI "METER SYSTEM : System Description" (type B).
Is the inspection result normal?
YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC "Removal and Installation".
NO >> Replace combination meter. Refer to MWI "Removal and Installation" (type A) or MWI "Removal and Installation" (type B).

Component Function Check 1.CHECK SLIP INDICATOR LAMP FUNCTION Check that slip indicator lamp in combination meter turns ON for approximately 2 seconds after ignition switch is turned ON. Is the ...
Sensor rotor
FRONT SENSOR ROTOR
FRONT SENSOR ROTOR : Removal and Installation
REMOVAL
The front wheel sensor rotor is an integral part of the wheel hub and bearing
assembly and can not be
replaced individually. When replacing the front wheel sensor rotor replace the
hub and bearing assembly.
Refer to ...
Refrigerant pressure sensor
Removal and Installation for Refrigerant Pressure
Sensor
REMOVAL
CAUTION:
Do not damage the condenser fins.
Perform lubricant return operation before each refrigeration
system disassembly. However, if a large amount of refrigerant
or lubricant is detected, do not perform lubricant retur ...