DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.CHECK SELF-DIAGNOSIS RESULTS
Check the self-diagnosis results.
Is above displayed on the self-diagnosis display?
YES >> Proceed to diagnosis procedure. Refer to BRC "Diagnosis Procedure".
NO >> Inspection End.
Regarding Wiring Diagram information, refer to BRC "Wiring Diagram".
NOTE: Check brake fluid level in brake reservoir tank before starting inspection.
1.CONNECTOR INSPECTION
Is the inspection result normal?
YES >> GO TO 2
NO >> Repair or replace as necessary.
2.CHECK BRAKE FLUID LEVEL SWITCH
Perform the brake fluid level switch component inspection. Refer to BRC"Component Inspection".
Is the inspection result normal?
YES >> GO TO 3
NO >> Replace brake fluid level switch. Refer to BR "Exploded View".
3.CHECK BRAKE FLUID LEVEL SWITCH HARNESS
2. Check continuity between combination meter
connector and ground.
Is the inspection result normal?
YES >> GO TO 4
NO >> Repair or replace malfunctioning components.
4.CHECK BRAKE FLUID LEVEL SWITCH GROUND CIRCUIT
Check continuity between brake fluid level switch connector E40 terminal 2
and ground.
Is the inspection result normal?
YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC "Removal and Installation"
NO >> Repair or replace malfunctioning components.
Component Inspection
1.CHECK BRAKE FLUID LEVEL SWITCH
Is the inspection result normal?
YES >> Inspection End.
NO >> Replace brake fluid level switch. Refer to BR "Exploded View".
DTC Logic DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1.CHECK SELF DIAGNOSTIC RESULT With CONSULT. Turn ignition switch OFF to ON. Perform self diagnostic result. Is ...
Rear oil seal
REAR OIL SEAL : Removal and Installation
REMOVAL
Remove transaxle assembly.
Remove clutch cover and clutch disk (M/T models).
Remove flywheel (M/T models) or drive plate (A/T or CVT models).
Remove rear oil seal with a suitable tool.
CAUTION:
Be careful not to damage crankshaft an ...
Power supply and ground circuit
Diagnosis Procedure
1.CHECK GROUND CONNECTION
Turn ignition switch OFF.
Check ground connection E. Refer to Ground Inspection in GI, "Circuit
Inspection".
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace ground connection.
2.CHECK ECM G ...