DTC DETECTION LOGIC
| DTC No. | Trouble diagnosis name (Trouble diagnosis content) | DTC detecting condition | Possible cause |
| P0037 | HO2 HTR (B1) (Heated oxygen sensor 2 heater control circuit low) | The current amperage in the heated oxygen sensor 2
heater circuit is out of the normal range.
(An excessively low voltage signal is sent to ECM through the heated oxygen sensor 2 heater.) |
|
| P0038 | HO2 HTR (B1) (Heated oxygen sensor 2 heater control circuit high) | The current amperage in the heated oxygen sensor 2
heater circuit is out of the normal range.
(An excessively high voltage signal is sent to ECM through the heated oxygen sensor 2 heater.) |
|
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
TESTING CONDITION: Before performing the following procedure, confirm that battery voltage is more than 11 V at idle.
>> GO TO 2.
2.PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT
With GST
Follow the procedure "With CONSULT" above.
Is 1st trip DTC detected?
YES >> Proceed to EC, "Diagnosis Procedure".
NO >> INSPECTION END
1.CHECK HO2S2 POWER SUPPLY CIRCUIT

Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace errordetected parts.
2.CHECK HO2S2 OUTPUT SIGNAL CIRCUIT

4. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES >> GO TO 3.
NO >> Repair or replace errordetected parts.
3.CHECK HEATED OXYGEN SENSOR 2 HEATER
Check the heated oxygen sensor 2 heater. Refer to EC, "Component Inspection".
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI, "Intermittent Incident".
NO >> GO TO 4.
4.REPLACE HEATED OXYGEN SENSOR 2
Replace heated oxygen sensor 2. Refer to EX, "Exploded View".
CAUTION: - Discard any sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner [commercial service tool (J4389718 or J4389712)] and approved Antiseize Lubricant (commercial service tool).
>> INSPECTION END
1.CHECK HEATED OXYGEN SENSOR 2 HEATER

Is the inspection result normal?
YES >> INSPECTION END
NO >> GO TO 2.
2.REPLACE HEATED OXYGEN SENSOR 2
Replace heated oxygen sensor 2. Refer to EX, "Exploded View".
CAUTION:
>> INSPECTION END
Passenger air bag module
Exploded View
1. Passenger air bag module 2. Instrument panel assembly
Pawl
Removal and Installation
WARNING:
Before servicing, turn ignition switch OFF, disconnect both the
battery negative and positive terminals,
then wait at least three minutes.
Always work from the side of ai ...
Trunk open function
TRUNK OPEN FUNCTION : System Description
System Diagram
TRUNK LID OPENER OPERATION
When the BCM detects that trunk lid opener switch is pressed, it starts
the outside key antenna (rear
bumper) and inside key antenna and transmits the request signal to the
Intelligent Key. Then, c ...