Nissan Versa (N17): Fuel level sensor signal circuit

Nissan Versa 2nd generation (N17) Service Manual / Driver information & multimedia / Meter, warning lamp & indicator (MWI) / Fuel level sensor signal circuit

Description

The fuel level sensor unit and fuel pump detects the approximate fuel level in the fuel tank and transmits the fuel level signal to the combination meter.

Component Function Check

1.COMBINATION METER INPUT SIGNAL

1. Select METER/M&A on CONSULT.

2. Using FUEL METER of DATA MONITOR, compare the DATA MONITOR value with the fuel gauge position.

Does monitor value match fuel gauge reading?

YES >> Inspection End.

NO >> Replace combination meter. Refer to MWI "Removal and Installation".

Diagnosis Procedure

Regarding Wiring Diagram information, refer to MWI "Wiring Diagram".

1.CHECK HARNESS CONNECTOR

1. Turn ignition switch OFF.

2. Check combination meter and fuel level sensor unit terminals (meter-side and harness-side) for poor connection.

Is the inspection result normal?

YES >> GO TO 2

NO >> Repair or replace terminals or connectors.

2.CHECK FUEL LEVEL SENSOR UNIT CIRCUIT

1. Disconnect combination meter harness connector M24 and fuel level sensor unit and fuel pump harness connector B44.

2. Check continuity between combination meter harness connector M24 terminal 4 and fuel level sensor unit and fuel pump harness connector B44 terminal 2.                   

3. Check continuity between fuel level sensor unit and fuel pump harness connector B44 terminal 2 and ground.                                                                   

Is the inspection result normal?

YES >> GO TO 3

NO >> Repair harness or connector.

3.CHECK FUEL LEVEL SENSOR GROUND CIRCUIT

1. Check continuity between combination meter harness connector M24 terminal 26 and fuel level sensor unit and fuel pump harness connector B44 terminal 5.                               

2. Check continuity between fuel level sensor unit and fuel pump harness connector B44 terminal 5 and ground.                                                                               

Is the inspection result normal?

YES >> GO TO 4

NO >> Repair harness or connector.

4.CHECK INSTALLATION CONDITION

Check fuel level sensor unit installation, and verify the float arm does not interfere or bind with the internal components in the fuel tank.

Is the inspection result normal?

YES >> Inspection End.

NO >> Install the fuel level sensor unit properly.

Component Inspection

1.REMOVE FUEL LEVEL SENSOR UNIT

Remove the fuel level sensor unit. Refer to FL"Removal and Installation".

>> GO TO 2.

2.CHECK FUEL LEVEL SENSOR UNIT

Check the resistance between fuel level sensor unit and fuel pump.                   

CHECK FUEL LEVEL SENSOR UNIT

*: When float rod is in contact with stopper.

Is inspection result OK?

YES >> Inspection End.

NO >> Replace fuel level sensor unit and fuel pump. Refer to

FL "Removal and Installation".

Washer fluid level switch circuit

Description Transmits the washer fluid level switch signal to the combination meter. ...

Other materials:

Clutch master cylinder
Exploded View 1. Reservoir hose 2. Master cylinder Removal and Installation CAUTION: Do not spill clutch fluid onto painted surfaces. If fluid spills, wipe up immediately and wash the affected area with water. Do not disassemble clutch master cylinder. NOTE: When removing compo ...

TCM
Exploded View 1. TCM 2. Bracket 3. Clip Front Removal and Installation CAUTION: When replacing TCM, note the "CVTF DETERIORATION DATE" value displayed on CONSULT "CONFORM CVTF DETERIORTN" in MAINTENANCE BOOKLET, before starting the operation. NOTE: When replacing the TCM and transaxle ...

Categories


© 2017-2025 Copyright www.niveguide.com
0.0081