DTC DETECTION LOGIC
| DTC | Trouble diagnosis name | DTC detection condition | Possible causes |
| P0847 | Transmission Fluid Pressure Sensor/Switch B Circuit Low | The secondary pressure sensor voltage is
0.09 V or less continuously for 5 seconds or
more under the following diagnosis conditions: - Diagnosis conditions - CVT fluid temperature: −20C (−4F) or more - TCM power supply voltage: More than 11 V |
- Harness or connector
(Secondary pressure sensor circuit is
open or shorted to ground) - Secondary pressure sensor - Control valve assembly |
DTC CONFIRMATION PROCEDURE
1.PREPARATION BEFORE WORK
If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition switch OFF and wait for at least 10 seconds, then perform the next test.
>> GO TO 2.
2.CHECK DTC DETECTION
With CONSULT
FLUID TEMP : −19C (−2.2F) or more
With GST
CAUTION: When the ambient temperature is −20C (−4F) or less and the engine is cold, warm up the engine for approximately 5 minutes.
Is "P0847"detected?
YES >> Go to TM "Diagnosis Procedure".
NO >> INSPECTION END
1.CHECK CIRCUIT BETWEEN TCM AND CVT UNIT (PART 1)

Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace malfunctioning parts.
2.CHECK CIRCUIT BETWEEN TCM AND CVT UNIT (PART 2)
Check continuity between TCM harness connector terminals and ground. 
Is the inspection result normal?
YES >> GO TO 3.
NO >> Repair or replace malfunctioning parts.
3.CHECK TCM INPUT SIGNALS

Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI "Intermittent Incident".
NO >> There is malfunction of secondary pressure sensor. Replace transaxle assembly. Refer to TM "Removal and Installation".
P0846 Transmission fluid pressure
SEN/SW BDTC Logic DTC DETECTION LOGIC DTC Trouble diagnosis name DTC detection condition Possible causes P0846 Transmission Fluid Pressure Sensor/Switch B Circuit Range/Per ...
EVAP canister vent control valve
Exploded View
1. EVAP canister 2. O-ring 3. EVAP canister vent control valve
4. EVAP canister vent control valve hose
Removal and Installation
NOTE:
The EVAP canister vent control valve can be removed without removing the EVAP
canister.
REMOVAL
Remove the EVAP canister protector cov ...
P0733 3GR Incorrect ratio
Description
This malfunction is detected when the A/T does not shift into 3GR position as
instructed by TCM. This is not
only caused by electrical malfunction (circuits open or shorted) but by
mechanical malfunction such as control
valve sticking, improper solenoid valve operation, etc.
DTC ...