Nissan Versa (N17): Positive crankcase ventilation

Inspection

1.CHECK PCV VALVE

With engine running at idle, remove PCV valve from rocker cover. A properly working valve makes a hissing noise as air passes through it. A strong vacuum should be felt immediately when a finger is placed over valve inlet.

Is the inspection result normal?

YES >> INSPECTION END

NO >> Replace PCV valve. Refer to EM, "Exploded View".

CHECK PCV VALVE

EVAP leak check

Inspection CAUTION: Do not use compressed air or a high pressure pump. Do not exceed 4.12 kPa (0.042 kg/cm2, 0.6 psi) of pressure in EVAP system. NOTE: Do not start engine. Improp ...

Removal and installation

ECM Exploded View 1. ECM bracket 2. ECM  : Vehicle front Removal and Installation CAUTION: Perform ADDITIONAL SERVICE WHEN REPLACING ECM. Refer to EC-122, "Work Procedure". ...

Other materials:

A-BAG Branch line circuit
Diagnosis Procedure WARNING: Always observe the following items for preventing accidental activation. Before servicing, turn ignition switch OFF, disconnect battery negative terminal, and wait 3 minutes or more. (To discharge backup capacitor.) Never use unspecified tester or other meas ...

The oil pressure warning lamp does not turn on
Description The oil pressure warning lamp stays of when the ignition switch is turned ON. Diagnosis Procedure 1.CHECK COMBINATION METER OIL PRESSURE WARNING LIGHT 1. Select METER/M&A on CONSULT. 2. Observe OIL W/L DATA MONITOR while operating the ignition switch. Is the inspection resul ...