Nissan Versa (N17): Positive crankcase ventilation

Inspection

1.CHECK PCV VALVE

With engine running at idle, remove PCV valve from rocker cover. A properly working valve makes a hissing noise as air passes through it. A strong vacuum should be felt immediately when a finger is placed over valve inlet.

Is the inspection result normal?

YES >> INSPECTION END

NO >> Replace PCV valve. Refer to EM, "Exploded View".

CHECK PCV VALVE

EVAP leak check

Inspection CAUTION: Do not use compressed air or a high pressure pump. Do not exceed 4.12 kPa (0.042 kg/cm2, 0.6 psi) of pressure in EVAP system. NOTE: Do not start engine. Improp ...

Removal and installation

ECM Exploded View 1. ECM bracket 2. ECM  : Vehicle front Removal and Installation CAUTION: Perform ADDITIONAL SERVICE WHEN REPLACING ECM. Refer to EC-122, "Work Procedure". ...

Other materials:

Recommended fluids/lubricants and capacities
The following are approximate capacities. The actual refill capacities may be a little different. When refilling, follow the procedure described in the "Do-it-yourself" section to determine the proper refill capacity. ...

5Th main gear assembly
Removal and Installation REMOVAL Move the shift selector to the 3rd gear position. Disconnect the shifter cable and the selector cable from shifter lever A and selector lever. Refer to TM, "Removal and Installation". CAUTION: Do not move shifter lever A and selector leve ...