Nissan Versa (N17): Blower motor

Nissan Versa 2nd generation (N17) Service Manual / Ventilation, heater & air conditioner / Ventilation system (VTL) / Blower motor

Exploded View

Exploded View

1. A/C unit assembly 2. Blower motor 3. Blower fan resistor

Removal and Installation

REMOVAL

  1. Disconnect the negative battery terminal. Refer to PG "Removal and Installation".
  2. Remove the lower knee protector (LH). Refer to IP "Exploded View".
  3. Remove the accelerator pedal assembly. Refer to ACC "Removal and Installation".
  4. Remove the brake pedal assembly. Refer to BR9 "Removal and Installation".
  5. Disconnect the harness connectors from the blower motor.
  6. Disconnect the harness connector from the thermo control amp.
  7. Remove the blower motor screw (A).
  8. Press the flange holding hook and turn blower motor counterclockwise.
  9. Remove the blower motor.

REMOVAL

INSTALLATION

Installation is in the reverse order of removal.

Other materials:

Cooling fan control
Cooling fan control : system diagram Cooling fan control : system description INPUT/OUTPUT SIGNAL CHART Sensor Input signal to ECM ECM function Actuator Crankshaft position sensor (POS) Camshaft position sensor (PHASE) Engine speed*1 Piston position Cool ...

U1000 CAN Comm circuit
DTC Logic DTC DETECTION LOGIC Diagnosis Procedure 1.CHECK DTC DETECTION With CONSULT. Turn ignition switch ON. Perform self diagnostic result. Is DTC U1000 detected? YES >> Proceed to diagnosis procedure. Refer to LAN "Trouble Diagnosis Flow Chart". NO >> Ref ...